Terminal Block Connections
EARTH/GROUND
Safety Earth/Ground
NEUTRAL
Neutral supply conductor
LIVE
100-240Vac, Live supply conductor
DAY/NIGHT
Connect to live for Night Mode
SYNC
Pulse from live at desired flash rate to synchronize, or
connect constantly to live for steady Red Beacon
DIM0
Connect Dim 0 to live for 30%, connect Dim 0 and 1 to live
for 10%
DIM1
Connect Dim 0 to live for 30%, connect Dim 0 and 1 to live
for 10%
RED FAULT A
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
RED FAULT B
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
WHITE FAULT A
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
WHITE FAULT B
Uncommitted solid state relay output (600V/40mA max,
20mA continuous)
Notes:
1: After initial power up there may be a few seconds of delay before flashing
begins.
2: The default red Beacon and White Strobe flash rate is 20 flashes per minute.
3: The sync signal is not required if there is no need to synchronize with another
strobe. In the absence of a sync signal, the Strobe and Red Beacon will default
to 20 FPM.
4: For maximum immunity from the effects of radiated interference, the cable
from the Control Box to Power Supply Cabinet should be shielded with the
screen grounded at both ends.