Terminal Block Connections 

 

EARTH/GROUND 
 

 

Safety Earth/Ground

 

NEUTRAL 

Neutral supply conductor 

LIVE 

100-240Vac, Live supply conductor 

DAY/NIGHT 

Connect to live for Night Mode 

SYNC 

Pulse from live at desired flash rate to synchronize, or 
connect constantly to live for steady Red Beacon

 

DIM0 

Connect Dim 0 to live for 30%, connect Dim 0 and 1 to live 
for 10%

 

DIM1 

Connect Dim 0 to live for 30%, connect Dim 0 and 1 to live 
for 10%

 

RED FAULT A 

Uncommitted solid state relay output (600V/40mA max, 
20mA continuous)

 

RED FAULT B 

Uncommitted solid state relay output (600V/40mA max, 
20mA continuous)

 

WHITE FAULT A 

Uncommitted solid state relay output (600V/40mA max, 
20mA continuous)

 

WHITE FAULT B 

Uncommitted solid state relay output (600V/40mA max, 
20mA continuous)

 

 

Notes: 
 
1:  After initial power up there may be a few seconds of delay before flashing 
begins. 
 
2:  The default red Beacon and White Strobe flash rate is 20 flashes per minute. 
 
3: The sync signal is not required if there is no need to synchronize with another 
strobe. In the absence of a sync signal, the Strobe and Red Beacon will default 
to 20 FPM.  
 
4: For maximum immunity from the effects of radiated interference, the cable 
from the Control Box to Power Supply Cabinet should be shielded with the 
screen grounded at both ends. 

 

 
 

 
 

Содержание D1RW-C13-006

Страница 1: ...ight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com INSTALLATION AND MAINTENANCE MANUAL FOR P N D1RW C13 006 100 230VAC 50 60 Hz 20 000cd w...

Страница 2: ...19 Fax 732 751 5778 Web www dialight com Sheet 2 of 14 Contents Page Overview 3 Options 3 Installation and Wiring 6 Switch Settings 8 Operation and Initial Test 10 Lightning Protection 10 Maintenance...

Страница 3: ...acon section controlled and monitored by a microcontroller circuit The red beacon type is determined by the top level part number selection either 2 000cd red or 170cd red to meet the Specific require...

Страница 4: ...t a default 20FPM or pulse the Sync input with 100 230Vac at the desired flash rate The flashing will synchronize to this pulsing The flashing duty cycle is 50 50 WRED Flashing Mode The Wred flashing...

Страница 5: ...____________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 5 of 14 Red Beacon L Fig...

Страница 6: ...uth Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 6 of 14 Installation and Wiring The Power supply cabinet is designed to mount vertically with power and interconne...

Страница 7: ...onnect Dim 0 to live for 30 connect Dim 0 and 1 to live for 10 RED FAULT A Uncommitted solid state relay output 600V 40mA max 20mA continuous RED FAULT B Uncommitted solid state relay output 600V 40mA...

Страница 8: ...owing a number of options to be set up as follows 1 2 3 4 ON ON OFF 1 White at night Red at night 2 WRED pattern for red 50 duty cycle for red 3 Relays pulse while OK Relays static 4 Relays open on fa...

Страница 9: ...9 of 14 Mounting the Light Engine Dialight recommends the installation of one or more lightning rods near the installed Light Engine The lightning rods should extend a minimum of three feet above the...

Страница 10: ...e between the light engine and power supply Do not force the connectors into their mating halves Carefully align the mating halves of the polarized connectors before tightening the locking ring 2 Conn...

Страница 11: ...ore installing or working on the light Each driver module has a red indicator light to indicate more than 50VDC present on its output In addition the capacitor board has red indicator lights one for e...

Страница 12: ...er or module is faulty Check modules receiving power Replace any faulty driver modules One or more White Strobe layers not lit but all Indicator LED s are lit on driver modules Cable between power sup...

Страница 13: ..._________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 13 of 14 Table 2 Recommended spare parts user replaceable parts Des...

Страница 14: ...e NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 14 of 14 Specifications Operating Temperature Range 40 C to 55 C Default flash rate 20 FPM W Red 30FPM Power Supply Specificatio...

Отзывы: