631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2010 Philips Group •
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lighting Systems
CTS3-13
Page 1 of 2
Central Trough System 1-Light T5 Per Section
G1107
Ordering Information
Family
Mounting
Shielding
Configuration
Output
Length (nom.)
Housing
Voltage
Option
CT3
G
L
A
CT3
G
= Grid Mount
L
= Flush
A
= 1 Lamp
1
H
= High
2
= 2-foot
U
= Indiv. Unit
2
1
= 120V
E
= EM Pack
4
Lens
Output
4
= 4-foot
S
= Starter
2
= 277V
T
= Tandem Switch
S
= Standard
8
= 8-foot
J
= Joiner
4
= 4 Through Wires
T
= Telescoping
3
5
= 5 Through Wires
D
= Dimming
5
3
5
6
7
1
2
4
5
1
/
8
" (13.02cm)
3" (7.62cm)
3
3
/
4
"
(9.53cm)
Complete ordering instructions below.
Features
1. Housing:
20 gauge pre-painted steel
2. Bulkhead:
18 gauge galvanized steel
3. Reflector:
semi-specular aluminum
4. Trim:
none visible, fixture drops into grid system by others
5. Ballast:
program start electronic
6. Lamp:
T5 or T5 HO fluorescent
7. Lens:
extruded frosted acrylic
Optional Extended Continuous Length Lens shown on page 2.
Mounting
Housing is suspended by hanger wires by others. Compatible with standard and slot
T grid systems. Optional factory provided Quick-Draw Installation System shown on
page 2.
Electrical
Electronic Ballast:
Programmed start, 3 conductor, 12 gauge wire.
Color-coded quick connectors allow easy connection for modular fixtures. T5HO
lamps are dimmed with Advance Mark 10. T5 standard output lamps are dimmed
with ULT Super Dim. Use compatible dimmers and feed wires. Factory installed
ballast disconnect allows the ballast to be disconnected from and reconnected to
incoming power under load without turning the entire circuit off.
Emergency Battery Pack:
450 Lumens @ 90 minimum.
Labels
UL, cUL and IBEW
Ordering Instructions
Individual Fixtures:
1.
Order number of INDIVIDUAL UNITS required.
Continuous Rows:
1.
Determine run length
2.
Order one Starter fixture
3.
Order one Telescoping fixture*
4.
Order remainder of Joiner fixtures
* For best one-lamp effect, use Telescoping fixture at longest length possible.
Continuous runs only - Prior to installing CTS3 in a grid ceiling, the installing
contractor must ensure that the fixture will set into two main runners, spaced 4"
(10.16cm) on center. No grid cross members are required except at the beginning
and end of the run.
1
Lamp is mounted diagonally and extends into adjacent fixture by 2-1/2" (6.35cm) in Starter, Joiner and Telescoping fixtures
2
8-foot Individual Unit not available in Grid Mount
3
Telescoping fixture ships 85-3/8" (216.85cm), adjustable down to 49-3/8" (125.41cm)
4
EM pack not available in 2-foot or Telescoping fixtures
5
Advance Mark X dimming not available in 2' fixtures