CAUTIONS

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety 

precautions should always be followed including the 

following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before 

installation.

DANGER

 – Risque de choc – Couper l’alimentation 

avant l’installation.

2.  This Product Must Be Installed In Accordance With The 

Applicable Installation Code By A Person Familiar With 

The Construction And Operation Of The Product And 

The Hazards Involved. 

Ce Produit Doit Être Installé Selon Le Code D’installation 

Pertinent, Par Une Personne Qui Connaît Bien Le 

Produit Et Son Fonctionnement Ainsi Que Les Risques 

Inhérents. 

3.  Suitable for Wet Locations.

 

Adspte pour les Endroits Mouiles.

4.  Suitable for mounting within 1.2 m (4 ft) of the ground. 

Peut être installé à moins de 1,2 m (4 pi) du sol.

5.  Keep combustible and other materials that can burn away 

from lamp/lens minimum 3 inches.

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE 

1. 

Connect cord leads inside wiring housing to fixture leads using 
supplied wire nuts. Connect cord green wire to fixture ground wire 
(green). Connect cord white wire to fixture common wire (white). 
Connect cord black wire to fixture voltage wire (black). See 

 

Figure 1.

2. 

Attach wiring housing to inner (4) threaded holes on fixture 

housing using supplied Allen bolts and Allen wrench. Tighten bolts 
to 132 in-lbs (14.9 N•m).

3.  Remove black plugs from (4) outer threaded holes. Attach upper 

yoke bracket to (4) outer threaded holes using supplied Allen bolts 
and Allen wrench. Tighten bolts to 132 in-lbs (14.9 N•m).

4. 

Mount fixture in intended location using (2)  customer supplied  
³⁄

8

" (10 mm) fasteners and washers appropriate for the mounting 

surface.  

NOTE: 

Slots in lower U-bracket can be used as a template for 

locating holes on mounting surface. 

5. 

Aim fixture by loosening (2) center bolts and removing (2) outer 
bolts on sides of  lower U-bracket. Rotate fixture to desired tilt 
angle. Once fixture is properly aimed, line up outer holes in upper 

and lower U-brackets. Reinsert bolts into outer holes of U-bracket 
to lock tilt angle. Tighten (4) bolts on sides of U-bracket to 132 
in-lbs (14.9 N•m).

6. 

Make wiring connections to cord leads exiting wiring housing per 

the 

Electrical Connections

 section.

U-BRACKET MOUNTING 

(Requires use of E-ACU-FFC-LRG Accessory)

 

FIGURE 1

Inner Threaded 

Holes

Outer 

Threaded 

Holes

Gasket

(8) Allen Bolts

Wiring 

Housing

Upper 

U-Bracket

Lower 

U-Bracket

Outer 

Threaded 

Holes

(1) Outer Bolt on Each 

side of U-Bracket

(1) Center Bolt on Each 

side of U-Bracket

Summary of Contents for E-FFC14 Series

Page 1: ...d green wire to fixture ground wire green Connect cord white wire to fixture common wire white Connect cord black wire to fixture voltage wire black See Figure 1 2 Attach wiring housing to inner 4 threaded holes on fixture housing using supplied Allen bolts and Allen wrench Tighten bolts to 132 in lbs 14 9 N m 3 Remove black plugs from 4 outer threaded holes Attach upper yoke bracket to 4 outer th...

Page 2: ...the tenon that the fitter will be mounted on 5 Route supply leads through open end of lower fitter and into splice compartment NOTE It may be necessary to disassemble the upper and lower portions of the adjustable fitter in order to run the leads into the splice compartment If disassembly is necessary remove the 8 10 mm bolt and lock washer inside the splice compartment and route leads into splice...

Page 3: ... Conecte el cable negro del cordón al cable de voltaje de la luminaria negro Ver Figura 1 2 Acople la carcasa de cableado con los orificios con rosca interior 4 a la carcasa de la luminaria usando los tornillos Allen y la llave Allen suministrados Apriete los tornillos a 132 lb pulg 14 9 N m 3 Retire los tapones negros de los 4 orificios con rosca exterior Una el soporte de yugo superior a los 4 ori...

Page 4: ...mpalmes quizá sea necesario desensamblar las porciones superior e inferior del adaptador ajustable Si es necesario desensamblar retire el tornillo de 8 10 mm y la arandela de seguridad dentro del compartimiento de empalmes y guíe los cables hacia el compartimiento de empalmes Vuelva a ensamblar las mitades superior e inferior y vuelva a colocar el tornillo de 8 y la arandela de seguridad No apriet...

Page 5: ...Branchez le fil noir du cordon au fil de tension du luminaire noir Voir Figure 1 2 Fixez le boîtier de câblage aux 4 trous filetés internes du boîtier du luminaire à l aide des boulons Allen et de la clé Allen fournis Serrez les boulons à 14 9 Nm 132 po lb 3 Retirez les fiches noires des 4 trous filetés externes Fixez le support d étrier supérieur aux 4 trous filetés externes à l aide des boulons Allen ...

Page 6: ...ties supérieure et inférieure du montant réglable afin de faire passer les fils dans le compartiment des jonctions de fils Si un démontage est nécessaire retirez le boulon de 10 mm 8 po et la rondelle de blocage à l intérieur du compartiment des jonctions de fils et acheminez les fils dans le compartiment des jonctions de fils Réassemblez les moitiés supérieure et inférieure et replacez le boulon de 10 ...

Reviews: