background image

IOL-PORTABLE

4

5

600008-0000EN · Rev 1 · 2020/07

3  DESCRIPTION

The IOL-Portable is the Industry 4.0 portable, self-powered and user friendly configurator for IO-Link sensors that accesses your 
sensor data and manages its parameters. There is no need for a PC and dedicated software.

Through a 5.5 in HD touchscreen display and dedicated Apps you can now:

 

ƒ

Have access to an advanced diagnostic, showing operating hours, number of detections, operating cycles and alarms

 

ƒ

Verify your sensor status, including current temperature, quality of run and process data

 

ƒ

Easily change the operating sensor parameters to better meet the process requirements (switchpoint mode, sensing distance, 
timing functions, PNP/NPN/push-pull, NO/NC). It is also possible to add favourite parameters to the homepage.

 

ƒ

Automatically download IODD files, through Wi-fi. As soon as you plug the sensor to one of the 3 connectors on the top of the 
device, if the IODD file is not already on the device memory, it automatically connects to the download area and shows all the 
data of the sensor.

Thanks to these innovations you can now manage and optimize your sensor very quickly and improve your processes and 
predictive maintenance.

3.1  CONTENTS OF THE BOX

 

ƒ

IO-Link Hand Held Master

 

ƒ

Cable with hooks 0.3 m with connector M12, 4 poles

 

ƒ

Protective holster

 

ƒ

Micro-USB Cable

 

ƒ

Quick Start Guide

Содержание IOL-Portable

Страница 1: ...UNIVERSAL IO LINK HANDHELD MASTER IOL PORTABLE USER MANUAL 600008 0000EN Rev 1 2020 07 ...

Страница 2: ...the box 5 4 FEATURES 6 4 1 General 6 4 2 IO Link interface 6 4 3 IODD file administration 6 4 4 Configuration file administration 6 4 5 Button function 6 4 6 Electrical ratings 6 4 7 Battery info 6 4 8 LED function 7 4 9 Environmental 8 4 10 Approval and markings 8 4 11 Accessories 8 5 UNBOXING 9 5 1 Switch ON your IOL Portable 9 5 2 Screen gestures 9 5 3 General info 9 6 SOFTWARE 10 6 1 Funktion ...

Страница 3: ...adiators or cookers Do not leave your device charging near flammable materials as there is a risk of fire Contact with liquid Do not expose the device to liquid or touch it with wet hands Any damage caused by liquid may be irreparable Batteries The device contains Li ion batteries Do not disassemble the device Do not destroy the batteries Never use battery that have been damaged Leave batteries aw...

Страница 4: ...IOL PORTABLE 4 600008 0000EN Rev 1 2020 07 2 STRUCTURE M8 3 wire M12 M8 4 wire Power Status Main battery LEDs indication main battery LEDs state indication Micro USB port Micro SD card port 5 5 ...

Страница 5: ...operating sensor parameters to better meet the process requirements switchpoint mode sensing distance timing functions PNP NPN push pull NO NC It is also possible to add favourite parameters to the homepage Automatically download IODD files through Wi fi As soon as you plug the sensor to one of the 3 connectors on the top of the device if the IODD file is not already on the device memory it automa...

Страница 6: ...clulded Import IODD file from Micro SD card 4 4 CONFIGURATION FILE ADMINISTRATION Micro SD card not inclulded Save and load device configuration files Internal memory Save and load device configuration files 4 5 BUTTON FUNCTION Battery status Short press will indicate battery level for 5 sec plus Reserved for future use minus Power button Hold for 3 sec to power on off your IOL Portable Short pres...

Страница 7: ...cates around 20 of the charge Flashing The main battery is almost discharged Please recharge your device Power LED green Steady on The device is switched on IO Link LED green Flashing IO Link communication is ready the sensor is not connected or it does not have IO Link communication enabled Steady on IO Link communication is established with the IO Link sensor connected Error LED red Flashing Err...

Страница 8: ...10 APPROVAL AND MARKINGS General reference EN62368 1 Radio ETSI EN 300 328 v2 1 1 Approvals 4 11 ACCESSORIES Micro USB power adapter not included DC 5V 1A current limited Only suitably rated and approved USB charger should be used with the equipment as per the National Regulations for the country of use Marked as LPS according to IEC 60950 1 or PS2 according to IEC 62368 1 Using any other may affe...

Страница 9: ...e battery icon on the Launcher home screen This device has a built in micro SD card reader A micro SD card can be used to upload IODD ZIP files to the device and transfer project files to from the device The micro SD card is detected on power up thus it must be inserted BEFORE the device is switched on 5 3 GENERAL INFO 5 UNBOXING 5 1 SWITCH ON YOUR IOL PORTABLE To switch on your IOL Portable press...

Страница 10: ...IOL PORTABLE 10 600008 0000EN Rev 1 2020 07 6 SOFTWARE 6 1 FUNCTION Home screen Settings Wi Fi switch Store Configuration Icon Time and date Battery info ...

Страница 11: ... your IOL Portable up to date and accept available software updates to get new and enhanced features Select the Store 2 Select Wi Fi 1 Select settings 3 Select to turn on the Wi Fi 4 Select one of the networks available from the list to connect the device to internet If requested insert the password ...

Страница 12: ... only one sensor at a time Close Configure App and go back to home screen Measurement value mm All process data Icon Details IO Link Parameterization Identification Observation Diagnosis Sensor connected successfully Example activated switching output 3 Loading IODD 2 Select the icon to start 1 Connect your sensor ...

Страница 13: ...ORTABLE 13 600008 0000EN Rev 1 2020 07 Sensor not connected Sensor unrecognized IODD file not found in the device Press the icon to download it automatically from internet Back to home screen Error messages ...

Страница 14: ...o add an user 5 Select the new users role via the drop down menu 3 2 1 5 Create a user parameterization settings users Rollen Functions Observer Maintenance Specialist Identification Check Check Check Observation Check Check Check Diagnosis Check Check Check Parameter Basic Check Check All Check John Doe 4 ...

Страница 15: ...t to open and touch 1 Select Settings 1 Touch to open a saved project 2 2 1 1 Project options parameterization save or load IODD options parameterization settings IODD Save or load a project Delete rename or load a project Delete or update the existing IODD file List of projects ...

Страница 16: ...SENSOR Selct Process data Example activated switching output Example activated switching output Measurement value mm All process data 3 Scroll verticallly to find the parameter 2 Select parameter details Configuration of switching output for a ultrasonic sensor 1 Select icon 1 2 3 ...

Страница 17: ...ead the parameters of the sensor Touch this to write the changes into the sensor Touch this to go ahead Touch this to go back to the previous parameter ATTENTION Don t forget Push if live mode is not active Parameter ultrasonic sensor Reset sensor to factory settings Configure switchpoint mode Window mode Reflex mode Single point mode Configure switchpoint logic NO NC Configure switchpoint 1 mm ...

Страница 18: ...n touch it 3 Touch to delete it Delete a favourite parameter Example of SO active 3 2 1 Add a parameter to the favourite list Scroll vertically to find the desired parameter for example NO NC configuration LO Logic Favourites list 1 Swipe left 2 Press to add it to the favourites list 1 2 ...

Страница 19: ...NS CLEVER PRACTICAL di soric All information is supplied without guarantee Contents may contain mistakes or print errors and are subject to technical changes 600008 0000EN Rev 1 202007 SOLUTIONS CLEVER PRACTICAL di soric GmbH Co KG Steinbeisstrasse 6 73660 Urbach Germany Phone 49 71 81 98 79 0 Fax 49 71 81 98 79 179 info di soric com www di soric com ...

Отзывы: