has better intelligence capabilities, meanwhile, mechanical dimensions and pin interface and
communication commands are compatible with V3.2, V3.2 has been reversed based on the following
changes:
Serial level selected from the skipped stitches to button, user can easily select RS232 or TTL-level
output level output by pressing the settings( after reboot ).
Modified the algorithm, so dead zone was reduced and enhance accuracy.
Analog voltage output, voltage and the measured distance is proportional.
Wide voltage s3.3V-5.0V.
Power reverse protection.
Automatic measurement of time interval can be modified.
Modify a servo controlled angle of 0-180, compatible with the most of the servos on the market.
Measuring time is 100ms.
Specification
Power: +3.3V
~
+5.0V
Current: <20mA
Working temperature: -10
~
+70
Detecting range: 5cm-500cm
Resolution: 1cm
Interface: RS232 (TTL), PWM
Size: 22mm × 51 mm
Weight: 25g
PinOut