- 4 -
1.
Installation
(1)
The recommended erection height is 2.5-3 meters
(2)
The recommended distance to the subjects is 3 meters
(3)
The thermal lens must be adjusted according to the environment.
(4)
Avoid strong light in the installation environment.
(5)
Outdoor ground temperature would affected by weather, please avoid capturing the
outdoor ground.
(6)
Thermal camera is unable to capture subjects blocked by glass.
(7)
Subjects shouldn’t be set under the air-conditioner, and avoid reflective objects,
reflective objects, and hot objects around, such as: stainless steel, mirror, glass,
electrical appliances, hot food, etc.
Содержание iMage-M
Страница 1: ...Multi Person Fever Detection With Mobotix M16 Thermal camera User s Manual ...
Страница 2: ... 2 Version information Version Content Date 1 0 First release 2020 05 EZMatch FaceSpecification ...
Страница 8: ... 8 Fill in the string below caption SEN TTR CELSIUS description ID ET0 ID ETHERNET 5 Send Port Set ...
Страница 19: ... 19 4 Interval of action An interval between events If immediate report is required please cancel 5 Press save ...