background image

www.dfi.com

CS170-Q370/C246/H310

Chapter 3

 

- BIOS Settings

40

When “CPU Smart Fan Mode” is set to “Manual mode”, the following field will appear.

Manual PWM Setting

Set the fan speed to a fixed value, ranging from 1-100%, 100% being maximum speed.

Serial Port Console Redirection

This section configures settings relevant to serial port console redirection.

Console Redirection

This field is used to enable or disable the console redirection function. When console redirec-

tion is set to enabled, console redirection settings are available as instructed below.

 

Advanced

 

NCT6116D HW Monitor

 

Advanced

Содержание CS170-C246

Страница 1: ...CS170 Q370 C246 H310 Mini ITX Industrial Motherboard User s Manual...

Страница 2: ...wners FCC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to...

Страница 3: ...SB Ports 19 Graphics Interfaces 19 COM Serial Ports 20 Audio 20 Internal I O Connectors 21 SATA Serial ATA Connectors 21 Cooling Fan Connector 22 Digital I O 22 LVDS LCD Panel 23 Chassis Intrusion Con...

Страница 4: ...You must take extra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it...

Страница 5: ...cable Length 500mm Thermal solution For 35W Height 37 3mm Thermal solution For 65W Height 72 8mm Thermal solution For 80W Height 77 1mm The board and accessories in the package may not come similar t...

Страница 6: ...ry Celeron G4900 Processor Core 2 Max speed 3 1 GHz TDP 54W support ECC memory Memory Dual Channel DDR4 2400 2666MHz C246 Two 260 pin ECC non ECC SODIMM up to 32GB Core i5 i7 only support non ECC Q370...

Страница 7: ...LPC WATCHDOG TIMER Output Interval System Reset Programmable via Software from 1 to 255 Seconds SECURITY TPM dTPM2 0 available upon request POWER Type ATX Connector 4 pin ATX 12V power 24 pin ATX powe...

Страница 8: ...ses the PCI PME Power Man agement Event signal However if your system is in the Suspend mode you can power on the system only through an IRQ or DMA interrupt Wake On USB This function allows you to us...

Страница 9: ...an antistatic wrist strap and attaching it to a metal part of the system chassis If a wrist strap is unavailable establish and maintain contact with the system chassis throughout any procedures requir...

Страница 10: ...ep 1 Features Two 260 pin SODIMM up to 32GB Dual Channel DDR4 2133 2400 2666MHz ECC memory supported by CS170 C246 The system board supports the following memory interface Single Channel SC Data will...

Страница 11: ...rd sounding a distinctive click and lock the card in place Inspect that the clip sits in the notch If not please pull the clips outward release and remove the card and mount it again Key Socket Top Vi...

Страница 12: ...t The CPU socket must not come in contact with anything other than the CPU Avoid unnecessary exposure Remove the protective cap only when you are about to in stall the CPU CPU 6 Remove the protective...

Страница 13: ...eated in the cor rect orientation Alignment key Alignment key CPU 8 Close the load plate then push the load le ver down While closing the load plate make sure the front edge of the load plate slides u...

Страница 14: ...when you purchase the fan heat sink assembly Do not spread the paste all over the surface When you later place the heat sink on top of the CPU the compound will disperse evenly Some heat sinks come wi...

Страница 15: ...S To load the default values stored in the ROM BIOS please follow the steps below 1 Power off the system and unplug the power cord 2 Put a jumper cap on JP1 s pin 2 and pin 3 Wait for a few seconds an...

Страница 16: ...Gen2 USB 3 1 Gen1 DP1 USB 7 9 USB 3 1 Gen1 USB 2 0 LAN1 COM1 COM2 VGA DP2 Audio 2 1 Chassis Intrusion Chassis Intrusion Chassis Intrusion 2 5 SM BUS Battery Battery Buzzer PCIe Gen3 x16 Realtek ALC88...

Страница 17: ...JP8 JP1 1 3 CPU Fan LVDS SATA1 R2 SATA0 ATX Power LVDS Inverter Power 1 1 39 2 8 1 1 1 Front Panel 8 1 DIO 1 4 DIO Power 1 3 System Fan 1 LPC LPC 2 8 SMI 10 2 USB7 8 USB 2 0 USB7 8 USB 2 0 12V Power...

Страница 18: ...Gen 2 USB 3 1 Gen 1 Mic in Line out Line in LAN 2 LAN 1 VGA COM 1 USB 2 0 DP COM 2 DP USB 3 1 Gen 1 USB 3 1 Gen 1 Q370 C246 H310 RJ45 LAN Ports The two LAN ports allow the system board to connect to a...

Страница 19: ...1 Gen 1 7 9 USB 3 1 Gen 2 1 2 USB 3 1 Gen 1 3 4 Graphics Interfaces DP Port The DisplayPort is a digital display interface used to connect a display device such as a com puter monitor It is used to t...

Страница 20: ...M 1 COM 2 Audio Rear Audio The system board is equipped with 2 audio jacks Line out and Mic in Line in jack is available upon request A jack is a one hole connecting interface for inserting a plug Lin...

Страница 21: ...e Features SATA Serial ATA Connectors DDR4_1 SODIMM DDR4_2 SODIMM Intel C246 Q370 H310 M 2 2280 M Key 6 5 2 1 JP4 1 2 5 6 JP5 JP7 1 1 3 3 JP10 6 5 2 1 JP8 JP1 1 3 CPU Fan LVDS SATA1 R2 SATA0 ATX Power...

Страница 22: ...provide PWM to modulate fan speed The 8 bit Digital I O connector provides powering on function to external devices that are con nected to these connectors Digital I O Digital I O Connector Pin Assign...

Страница 23: ...l Power 39 Panel Power 40 Panel Power LVDS LCD Panel Connector LCD Inverter Power Connector Pin Function 1 GND 2 GND 3 Panel Inverter Brightness Voltage Control 4 Panel Power 5 3 3V 6 Panel Backlight...

Страница 24: ...Disk Drive LED Lighting of the LED indicates that the hard drive is being accessed RESET Reset Switch This switch allows you to reboot without having to power off the system PWR LED Power Standby LED...

Страница 25: ...oard 4 Make sure the notch on card is aligned to the key on the socket 5 Make sure the standoff screw is removed from the standoff M 2 Module M 2 Socket Key Stand off Notch Internal I O Ports Internal...

Страница 26: ...nnect to the second line out and mic in jacks that are at the front panel of your system Pin Assignment Pin Assignment 1 Mic2 L 2 GND 3 Mic2 R 4 N C 5 Line2 R 6 Mic2 JD 7 GND 8 9 Line2 L 10 Line2 JD F...

Страница 27: ...6 5 2 1 JP8 JP1 1 3 CPU Fan LVDS SATA1 R2 SATA0 ATX Power LVDS Inverter Power 1 1 39 2 8 1 1 1 Front Panel 8 1 DIO 1 4 DIO Power 1 3 System Fan 1 LPC LPC 2 8 SMI 10 2 USB7 8 USB 2 0 USB7 8 USB 2 0 12...

Страница 28: ...SB7 8 USB 2 0 USB7 8 USB 2 0 12V Power 1 2 9 Front Audio LAN1 LAN2 USB 3 4 USB 3 1 Gen1 USB 1 2 USB 3 1 Gen2 USB 3 1 Gen1 DP1 USB 7 9 USB 3 1 Gen1 USB 2 0 LAN1 COM1 COM2 VGA DP2 Audio 2 1 Chassis Intr...

Страница 29: ...t Audio LAN1 LAN2 USB 3 4 USB 3 1 Gen1 USB 1 2 USB 3 1 Gen2 USB 3 1 Gen1 DP1 USB 7 9 USB 3 1 Gen1 USB 2 0 LAN1 COM1 COM2 VGA DP2 Audio 2 1 Chassis Intrusion Chassis Intrusion Chassis Intrusion 2 5 SM...

Страница 30: ...t require an operating system to run After you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appe...

Страница 31: ...r displays the year from 2005 to 2099 Scroll down the screen to reveal the rest of the fields System Time The time format is hour minute second The time is based on the 24 hour military time clock For...

Страница 32: ...wer management related settings in this page Wake system from S5 via RTC When Enabled the system will automatically power up at a designated time every day from the Real time clock RTC battery More se...

Страница 33: ...utilize the additional hardware capabilities provided by Vanderpool Technology Active Processor Cores Select number of cores to be enabled in each processor package all 1 2 3 4 or 5 Hyper threading E...

Страница 34: ...ure Intel R Active Management Technology Parameters Please refer to the following pages ME Unconfig on RTC Clear When disabled ME will not be unconfigured on RTC Clear Firmware Update Configuration Pl...

Страница 35: ...ing pages OEM Flags Settings Please refer to the following pages AMT Configuration Secure Erase Configuration This section is used to configure Secure Erase Secure Erase Mode Select Secure Erase modul...

Страница 36: ...rompt when attempting ME unconfigu ration Unconfigure ME Enable or disable to unconfigure ME with resetting MEBx password to default Me FW Image Re Flash This field is used to enable or disable the Me...

Страница 37: ...r the security device Your computer will reboot during restart in order to change state of the security device PTN3460 Function Enabled or Disabled PTN3460 LCD Features LCD Panel Type Select the resol...

Страница 38: ...nit Select WatchDog Timer Unit Second or Minute SuperIO WatchDog Timer Set SuperIO WatchDog Timer Timeout value The range is from 0 disabled to 255 Serial Port 1 2 Configuration Configure the paramete...

Страница 39: ...ich speed the fan will always be fixed regardless of system temperature When CPU Smart Fan Mode is set to SMART FAN IV the following fields will appear Boundary 1 to Boundary 4 Set the boundary temper...

Страница 40: ...ranging from 1 100 100 being maximum speed Serial Port Console Redirection This section configures settings relevant to serial port console redirection Console Redirection This field is used to enabl...

Страница 41: ...Bits Flow Control VT100 115200 8 None 1 None Terminal Type Select terminal type VT100 VT100 VT UTF8 or ANSI Bits per second Select serial port transmission speed 9600 19200 38400 57600 or 115200 Data...

Страница 42: ...controls Legacy UEFI ROMs priority Network This field controls the execution of UEFI and Legacy Network OpROM Storage This field controls the execution of UEFI and Legacy Storage OpROM Video This fiel...

Страница 43: ...4 PXE Support Enable or disable IPv4 PXE boot support If disabled IPv4 PXE boot support will not be avail able Ipv6 PXE Support Enable or disable IPv6 PXE boot support If disabled IPv6 PXE boot suppor...

Страница 44: ...ce to be the primary display Auto IGFX PEG PCI Internal Graphics Keep IGFX enabled based on the setup options Graphics Configuration Enable Root Port Enable or disable the root port Max Link Speed Con...

Страница 45: ...lowing pages SATA And RST Configuration Please refer to the following pages HD Audio Configuration Please refer to the following pages LAN1 I219 Enable or disable onboard NIC Wake on LAN Enable Enable...

Страница 46: ...le the PCI express root port PCIe Speed Select the speed of the PCI Express root port Auto Gen1 Gen 2 or Gen3 This field will not appear when the root port does not support speed configuration PCI Exp...

Страница 47: ...m Acceleration This option allows you to create RAID or Intel Rapid Storage configuration with Intel Optane system ac celeration on Serial ATA devices Use RST Legacy OROM This field is only available...

Страница 48: ...oader is not tampered by malware System Mode This field displays whether the system is in User or Setup mode Secure Boot Enable or disable Secure Boot Please reset the platform after changing the sett...

Страница 49: ...then press Enter A dialog box will appear Select Yes to reset the system after saving all changes made Discard Changes and Reset To discard the changes select this field and then press Enter A dialog...

Страница 50: ...ill not be updated and will cease to be effective Updating the BIOS To update the BIOS you will need the new BIOS file and a flash utility Please contact techni cal support or your sales representativ...

Страница 51: ...0 and RAID 1 Use four new drives or an existing drive and three new drives for this configuration RAID Level Min Drives Protection Description RAID 0 2 None Data striping without redundancy RAID 1 2 S...

Страница 52: ...or SATA drives It enables enhanced performance and power management for the storage sub system Step 3 Create a RAID Volume 1 Go to the Advanced menu of the AMI BIOS and select Intel R Rapid Storage Te...

Страница 53: ...the AMI BIOS 2 In the Advanced menu select PCH FW Configuration 3 Select Enabled in the AMT BIOS Features field Configure Management Engine Technology Parameters Aptio Setup Utility Copyright C 2019 A...

Страница 54: ...Save Options Save Changes and Reset Discard Changes and Reset Restore Defaults Boot Override Save Setting to file Restore Setting from file Chipset Advanced Main Security Boot Save Exit Select Screen...

Страница 55: ...tel R ME v12 0 40 1433 Copyright C 2003 17 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Enabled Intel R AMT Configuration MEBx Exit Intel R ME Pas...

Страница 56: ...ord in the space provided under Intel R ME Password then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 40 1433 Copyright C 2003 17 Intel Corporation All Rights Res...

Страница 57: ...And Configuration Power Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes 13 In the Intel R AMT Configuration menu select SOL Storage Redirecti...

Страница 58: ...light Enter Complete Entry Esc Discard Changes 16 Select KVM Feature Selection then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v12 0 0 0010 Intel...

Страница 59: ...oose to use a password only during setup and configuration or to use a pass word anytime the system is being accessed Intel R Management Engine BIOS Extension v12 0 0 0010 Intel R ME v12 0 40 1433 Cop...

Страница 60: ...ME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update 24 Select Domain Name then press Enter Enter the computer s domain name then press Enter Intel R Management Engine BIOS Exten...

Страница 61: ...3 Copyright C 2003 17 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit TCP IP SETTINGS Wired LAN IPV4 Configuration 27 Select Periodic Update Interval then press Enter...

Страница 62: ...0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 32 Select Subnet Mask Address then press Enter Enter address then press Enter Intel R Management...

Страница 63: ...C 2003 17 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask Address 0 0 0 0 Default Gateway Address 0 0 0 0 Preferred DNS Address 0...

Страница 64: ...ent Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 40 In the Intel R Remote Setup And Configuration menu select Pro...

Страница 65: ...d INTEL R REMOTE CONFIGURATION Start Configuration Move Highlight Enter Select Entry Esc Exit This will activate Remote Configuration Continue Y N 44 Press Esc until you return to the Intel R Remote S...

Страница 66: ...256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Active Default Algorithm VeriSign Class 3 VeriSign Class 3 Go Daddy Class...

Отзывы: