Packing Replacement
Removing the Old Packing
1. Relieve the pressure in the pipeline and close the valve.
2. If the actuator is powered, disconnect and lock out power to prevent accidental operation of the ac-
tuator.
3. Remove the two screws and nuts near the top of the gate and disengage the stem from the gate by
stroking the actuator (not the valve) to the open position.
4. Remove the gland nuts (A7), bolts (A5) and packing gland (A4).
5. Remove the used packing (A2), anti-extrusion ring (A9) if supplied and packing cord (A8) if sup-
plied, from the packing chamber.
June 2019
Page 9
D10411
DeZURIK
2-24” KGC ES or HD KNIFE GATE VALVES
WARNING!
Pipeline pressure can cause personal injury or equipment damage. Relieve pipe-
line pressure before removing gate stem and packing gland nuts.
WARNING!
Accidental operation of power actuator can cause personal injury or equipment
damage. Disconnect and lock out power to actuator before servicing.