Operation
The gate in the valve is positioned by the valve actuator. The actuator moves the gate over the valve
port in the closed position, and withdraws the gate from the seat in the open position. Refer to the Ac-
tuator Instructions for adjustment and maintenance requirements for the actuator.
Lubrication
The valve does not require lubrication. If applicable, ensure that valve threaded stems are maintained
with proper lubrication. Refer to the Actuator Instructions for lubrication requirements for the actuator.
Packing
The gate packing is contained and compressed by the packing gland. See Figure 2 for component
identification.
Note:
The packing gland is slightly loosened prior to shipping. This is done to increase the life of the
packing during extended storage.
Adjustment
If packing leaks, tighten the adjustment nuts on top of the packing gland. Tighten the nuts evenly and
gently just enough to stop the leak. Over tightening will cause excessive operating forces, and will de-
crease the life of the packing.
June 2019
Page 7
D10411
DeZURIK
2-24” KGC ES or HD KNIFE GATE VALVES