- 17 -
5.4 Max. over current protec�on device
In order to protect the inverter AC connec�on, it is recommended to install a circuit breaker to
prevent overcurrent. See table 5.3 below.
Rated output
voltage(V)
Inverter
Rated output
current(A)
Current for protection
device(A)
Table 5.3 Recommended current protector specifica�ons
5.5 Inverter monitoring connec�on
Pic 5.12 Internet monitoring solu�on
PC
Web Server
Smart Phone
Router
GPRS
WIFI
Internet
Inverter has the func�on of wireless remote monitoring. The inverter with Wi-Fi func�on is
equipped with Wi-Fi Plug to connect the inverter and network. Wi-Fi Plug's opera�on,
installa�on, Internet access, APP downloading and other processes are detailed in the
instruc�ons.
SUN-9K-G
230
50
SUN-10K-G
230
39.1
43.5
60
SUN-10.5K-G
230
45.7
60
SUN-7.5K-G
230
50
SUN-8K-G
230
32.6
SUN-7K-G
230
50
30.4
34.8
50