![Dexter Laundry WCVD Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dexter-laundry/wcvd-series/wcvd-series_troubleshooting-and-fault-codes_2490408009.webp)
Fault# Description
Customer Action
F26
VFD unit has been added or
loose connection.
Soft reset control.
F27
Injection relay PCB has been
added to machine or loose
connection.
Soft reset control.
F28
Optional water valve PCB
has been added or loose
connection
Soft reset control.
Note:
Whenever power is turned off to the washer, it must remain off for three minutes for
drive to reset. The washer will not operate correctly if this is done improperly. This will allow
most fault codes to reset that are displayed at washer front. A fault code F-13 or F-21 will
appear on front display if this procedure has not been reset correctly. Note: Should a power
loss occur during cycle and then power returns, P U S H will be displayed and customer must
push a temperature selection button to continue the cycle.
9
Part # 8533-074-001 09/13
Содержание WCVD Series
Страница 1: ...8533 074 001 09 13 WCVD Series OPL Washers Troubleshooting And Fault Codes Starting serial number...
Страница 12: ...20Lb non Express 120 Volt Wiring Schematic 12 Part 8533 074 001 09 13...
Страница 13: ...20Lb non Express 120 Volt Wiring Diagram 13 Part 8533 074 001 09 13...
Страница 14: ...20Lb Non Express 208 240V Wiring Schematic 14 Part 8533 074 001 09 13...
Страница 15: ...20Lb Non Express 208 240 Volt Wiring Diagram 15 Part 8533 074 001 09 13...
Страница 16: ...20Lb Express 208 240 Wiring Schematic 16 Part 8533 074 001 09 13...
Страница 17: ...20Lb Express 208 240 Wiring Diagram 17 Part 8533 074 001 09 13...