Fault# Description

Customer Action

F13

The variable frequency 
drive (VFD) and the 
washer computer are not 
communicating.

Check the data communication cable between the 
washer computer and the variable frequency drive 
(VFD).

Step 1: 

Make sure the cable did not become 

unplugged during operation.

Step 2:

 Make sure that the cable is not being pulled 

sideways at either the washer controller, or the VFD, 
plug end. If both ends of the communications cable are 
plugged in the washer computer and VFD and there is 
no tension on the communications cable pulling it from 
side to side, then replace the cable.\

Step 3:

 Inspect both female connection points at PCB 

controller and at VFD. These may need replacement if 
they cannot be reset.

F14

Over-current on the drive or 
motor.

Step 1:

 Check to make sure the washer cylinder turns 

freely by hand. If it turns freely, continue to step 2. If 
it does not, remove the belt and see if the motor turns 
freely by hand. If the motor turns freely, then check for 
obstructions in the cylinder or check the bearings. If 
the motor does not turn freely, replace the motor.

Step 2:

 Check the motor wires for a short circuit 

between leads. If there are motor leads that have 
conductors touching, separate them and insulate them. 
If the wires are broken, splice them together or replace 
the motor.

Step 3:

 Check braking resistors to see if they measure 

the correct resistance. If a resistor does not measure 
the proper value, replace it.

F15

The variable frequency 
drive (VFD) senses that 
the internal voltage is too 
high. The source of the 
problem can originate from 
two different areas. Area 
1: The input voltage can be 
too high, or there may be a 
high level of electrical noise. 
Area 2: The motor can be 
generating a voltage that is 
acting like an input to the 
VFD output motor terminals.

Step 1:

 Measure the supply voltage to the VFD on 

the L1, L2 (or N), and L3 (if connected to three phrase 
power). the supply voltage should be from 187 to 
264 VAC or 108 to 132 VAC for a 120 VAC VFD. Also 
make sure the supply wires on L1, L2 (or N) and 
L3 (if connected to three phase power are securely 
connected.

Step 2: 

Ch eck the braking resistor connections at the 

VFD. The terminal screws should be tight. Once of the 
braking resistor wires should be connected to terminal 
B2.

Step 3: 

Measure each braking resistor separately to 

make sure they are the correct resistance. (200 for 1 
and 2 Hp VFD and 160 for 3 Hp VFD).

Step 4:

 If you have a 240 VAC, high leg voltage 

supply, try disconnecting the high leg. If this cures 
the problem, either leave the high leg disconnected, 
connect a transient voltage surge suppressor (with 

some form of fi ltering) at the voltage supply panel, 
connect a line choke on the high leg or install a VFD 
fi lter.

7

Part # 8533-074-001 09/13

Содержание WCVD Series

Страница 1: ...8533 074 001 09 13 WCVD Series OPL Washers Troubleshooting And Fault Codes Starting serial number...

Страница 2: ...replace solenoid Door Switch Check for continuity through door latch switch when door closed If no continuity adjust or replace door switch Door will not open Thermoactuator Check to see if thermoactu...

Страница 3: ...ontinuity check pressure switch hose for obstruction If hose okay change pressure switch Water comes in but level does not rise Drain Valve open Check these areas Drain valve blockage Drain valve moto...

Страница 4: ...cross terminals 21 22 indicating pressure switch has reset to the empty posi tion If no continuity change pressure switch Machine starts and does not operate VFD Check yellow enable wires from relay P...

Страница 5: ...r pressure Check for blocked or restricted water flow Check to ensure the drain valve is functioning properly This error will occur on 18 washers when water level is set for high the pressure switch i...

Страница 6: ...be is clear of any blockage and the pressure switch is operating properly Check the pressure switch harness F9 The washer tub does not reach the spin target frequency within 150 seconds The wash cycle...

Страница 7: ...them together or replace the motor Step 3 Check braking resistors to see if they measure the correct resistance If a resistor does not measure the proper value replace it F15 The variable frequency dr...

Страница 8: ...r and test See Note Measure the incoming line voltage F20 Internal drive error Check VFD fault code before turning off power Turn the power off to the washer Wait one minute Turn the power on to the w...

Страница 9: ...o the washer it must remain off for three minutes for drive to reset The washer will not operate correctly if this is done improperly This will allow most fault codes to reset that are displayed at wa...

Страница 10: ...problem Reset drive CE14 Command message includes unused characters Possible controller problem Reset drive Normal operation of the VFD VFD display shows operating frequency first very quickly then c...

Страница 11: ...o the drive Check VFD fault code before turning off power Check the wiring connections to the drive and motor Check the ground wiring of the drive motor and incoming connection to ensure a proper grou...

Страница 12: ...20Lb non Express 120 Volt Wiring Schematic 12 Part 8533 074 001 09 13...

Страница 13: ...20Lb non Express 120 Volt Wiring Diagram 13 Part 8533 074 001 09 13...

Страница 14: ...20Lb Non Express 208 240V Wiring Schematic 14 Part 8533 074 001 09 13...

Страница 15: ...20Lb Non Express 208 240 Volt Wiring Diagram 15 Part 8533 074 001 09 13...

Страница 16: ...20Lb Express 208 240 Wiring Schematic 16 Part 8533 074 001 09 13...

Страница 17: ...20Lb Express 208 240 Wiring Diagram 17 Part 8533 074 001 09 13...

Отзывы: