![Dexter Laundry WCVD Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dexter-laundry/wcvd-series/wcvd-series_troubleshooting-and-fault-codes_2490408011.webp)
Fault# Description
Customer Action
OL or
OU
Overload of the drive or
motor
(Check drive fault code before powering down). Check
the washer motor to ensure it turns freely. Check
the wiring for loose connections to the drive and
motor. Measure the braking resistor values. Check for
damaged motor wires. Check V-Belt tension and adjust
to 1” defl ection at center. Check braking resistors.
GF
Ground Fault to the drive
Check VFD fault code before turning off power. Check
the wiring connections to the drive and motor. Check
the ground wiring of the drive, motor and incoming
connection to ensure a proper ground is present. Check
for damaged motor wires.
LU
Low Voltage to the drive
Check VFD fault code before turning off power.
Turn the power off to the washer. Check the wiring
connections to the drive and motor. If no problem is
observed, turn on power to the washer and test. (See
Note) Measure the incoming line voltage.
Variable Frequency Drive Control
Digital Readout Faults
11
Part # 8533-074-001 09/13
11
Содержание WCVD Series
Страница 1: ...8533 074 001 09 13 WCVD Series OPL Washers Troubleshooting And Fault Codes Starting serial number...
Страница 12: ...20Lb non Express 120 Volt Wiring Schematic 12 Part 8533 074 001 09 13...
Страница 13: ...20Lb non Express 120 Volt Wiring Diagram 13 Part 8533 074 001 09 13...
Страница 14: ...20Lb Non Express 208 240V Wiring Schematic 14 Part 8533 074 001 09 13...
Страница 15: ...20Lb Non Express 208 240 Volt Wiring Diagram 15 Part 8533 074 001 09 13...
Страница 16: ...20Lb Express 208 240 Wiring Schematic 16 Part 8533 074 001 09 13...
Страница 17: ...20Lb Express 208 240 Wiring Diagram 17 Part 8533 074 001 09 13...