Symptom
Probable Cause
Suggested Remedy
Erratic display
Initial Start-up
If erratic on initial start-up, leave power on for
approximately one hour and check machine
operation again.
Grounding
Machine must be grounded by separate conductor
back to neutral bar in breaker box.
Program
Check program and make corrections if
necessary.
Voltage spike
Power down machine for 20 seconds and
repower. If no improvement, replace control.
Manual overtemp
Tripping Frequently
Recirculating
chamber Lint
Accumulation
Remove manual overtemp thermostat and inspect
in chamber for excessive lint build up. Access also
gained to this chamber by removing recirculation
duct mounted at bottom of chamber, or the panel
inside burner chamber between burners and rear
back panel
Exhaust ducting
Excessive lint buildup
Remove exhaust duct at rear of dryer and inspect
for excessive lint build up in complete duct from
dryer to where duct exits building.
Clean linto of of top
heat air chamber
above tumbler
Remove front panel completely. Be careful of any
wiring attached. Remove heated air chamber
cover and clean above tumbler back to burner
housing.