DIMAX
804KC User’s Manual
40
DEXON Systems
CLEAR_LAYOUT
clear_layout - Request
Request message:
<
clear_layout
id
=
"
n
"
needack
=
"
{Yes|No}
"
/>
Description:
The
clear_layoutt
request is used to remove the information stored in the layout identified by
id
.
Attributes:
•
id
: layout identifier
RECALL_LAYOUT
recall_layout - Request
Request message:
<
recall_layout
id
=
"
n
"
needack
=
"
{Yes|No}
"
/>
Description:
The
recall_layout
request is used to set the arrangement stored in the layout identified by
id
to
the DIMAX device.
Attributes:
•
id
: layout identifier
SAVE_LAYOUTS
save_layouts - Request
Request message:
<
save_layouts
/>
Description:
The
save_layouts
request is used to query the whole layout configuration in order to save it for
future loading. This request is available only for clients with administrator privilege.
save_layouts - Reply
Reply message:
<
save_layouts
>
...
</
save_layouts
>
Description:
The DIMAX server sends
save_layouts
reply message to the client in response to the
save_layouts
request.