background image

Installing The Control

WARNING:

 Turn off circuit breaker or remove fuse(s) and test that power is 

off before wiring. Wiring the control live can cause serious risk of electrical 

shock and/or damage the control, voiding the warranty. For safety, this 

product must be installed in a grounded wall enclosure. If you are unfamiliar 

with methods of installing electrical wiring, secure the services of a qualified 

licensed electrician. Use only copper wire, do 

not

 use aluminum wire with 

this device.

ELECTRICAL SHOCK WARNING:

 This control is an automatic on device. 

At no time should a person work on the fan/light or any appliance connected 

to this control without the electrical circuit breaker or fuse switched off. This 

CONTROL could turn on the attached device by the unintended presence of 

condensation while the work is being performed. Always disconnect the AC 

power before any work is done to any part of the circuit this CONTROL is 

connected to. If you do not understand this warning, seek the services of a 

qualified licensed electrician.

CAUTION:

 

• Never place the CONTROL where it can be reached from a tub or shower.

• Use only a 120V AC 60Hz power supply connection.

• For indoor use only.

• Do not exceed the CONTROL’s maximum electrical load ratings, as 

• 

indicated on the product label.

• Must be installed and used in accordance with your local electrical codes.

• If a bare copper or green ground connection is not available in the wall 

• 

box, contact a qualified licensed electrician for installation.

• For use with permanently installed 120V AC powered fans only.

• Use only #14 or #12 copper wire connections.

IMPORTANT:

 Read each step carefully and perform in sequence. The 

CONTROL will not work or will become damaged if wires are connected 

incorrectly. To prevent damage, connect the CONTROL exactly as shown in 

the installation diagrams, otherwise warranty will be voided. Prior to wiring, 

straighten or clip ends of wire such that ends of each wire are straight (if 

using the CONTROL to replace an existing switch). Strip wire insulation at 

the end of each wire to expose 16 mm (0.63 in) of copper. Where instructed 

to make a connection, twist ends of stripped wires together and twist a 

proper connector clockwise until secure.

WARNING:

 To avoid fire or risk of electrical shock, turn off power at circuit 

breaker or disconnect fuse. Test the power is off before you begin wiring.

1.) For new installations, install a 8.9 cm (3.5 in) deep single-gang or multi-gang 

electrical wall enclosure, or (replacement of existing switch) remove existing wall 

plate and switch device being replaced.

2.) Attach 120V AC 60Hz 3-wire power (Hot / Neutral / Ground) inside the wall 

enclosure with a minimum of 15.2 cm (6 in) leads. Attach fan three wire leads 

inside the wall enclosure also with minimum 15.2 cm (6 in) leads. If an existing 

power connection is used in an existing wall enclosure you must confirm proper AC 

120V Hot / Neutral / Ground are available.

3.) Attach wires. Make sure the wall enclosure, fan, and the CONTROL are properly 

grounded. Make sure ground wire is securely fastened. Tighten all ground screws 

or wire nuts securely. Use the proper sized wire nut for #14 or #12 wire. Make sure 

to strip back the copper wire 1.6 cm (5/8 in) and twist wire and nut clockwise.

14

Содержание Breeze Easy

Страница 1: ...LISTED Installation Guide Read and Save These Instructions Need Help Service DewStop com 1 360 876 2974 English or 1 800 615 5439 French DewStop breeze easyTM model F200 1W...

Страница 2: ...ng The Control Using The Control Testing The Control Air Drafts In Wall Enclosure Frequently Asked Questions 5 Year Limited Warranty Model Exhaust Diameter Voltage V Frequency Hz Power W Air Flow At 0...

Страница 3: ...hese Instructions Need Help Service DewStop com 1 360 876 2974 English or 1 800 615 5439 French DewStop breeze easyTM model F200 1W TEMPLATE Qty 1 WIRE NUT Qty 4 SETTINGS TOOL Qty 1 MOUNTING SCREW Qty...

Страница 4: ...nimal bends 6 Use 120 V 60 Hz for the electrical supply and properly ground the unit Follow all local safety and electrical codes 7 Do not use this fan with any solid state control device such as a di...

Страница 5: ...on use the provided cutout TEMPLATE for the ceiling GRILLE edge should overlap finished ceiling Not for use in cooking area see installation instructions Do not install ventilation fan in areas where...

Страница 6: ...se and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can re...

Страница 7: ...its two springs Squeeze each spring together and pull down again to release the springs from the motor plate slots 3 Your existing fan may be attached in several ways Look for attachment screws in th...

Страница 8: ...Unscrew the face plate and your old switch 4 Disconnect your old switch from your existing wiring 5 The CONTROL comes with a single gang decora style face plate If you have a multi gang switch locatio...

Страница 9: ...g 2 Remove DAMPER from HOUSING Attach DAMPER to 10 2 cm 4 in ducting Use a length of flex ducting 61 cm 2 ft maximum Hide DAMPER and ducting in ceiling placing DAMPER next to where it will later be re...

Страница 10: ...presents before connecting You may need to consult a qualified licensed electrician to determine this safely black back white white green green yellow conduit power from CONTROL HOUSING 5 Place the in...

Страница 11: ...ther and inserting the springs into the slots in the MOTOR MOTOR HOUSING electrical plug screws mounting springs GRILLE ceiling flex ducting conduit SUPPORT STRIPS ROUNDHEAD WOOD SCREWS Qty 4 ceiling...

Страница 12: ...provided WIRE NUTS matching wire colours as shown WARNING Disconnect the AC power before any work is done to any part of the circuit Breeze Easy is connected to If you do not understand this warning...

Страница 13: ...rom CONTROL through conduit ceiling conduit ceiling flex ducting conduit DAMPER HOUSING DAMPER HOUSING 4 Attach DAMPER to 10 2 cm 4 in ducting Use a length of flex ducting 61 cm 2 ft maximum 5 Attach...

Страница 14: ...persons disconnect or turn off the breaker and lock the power supply at the panel to prevent the power from being turned on before servicing or cleaning the unit 1 Remove the GRILLE by squeezing the s...

Страница 15: ...tly installed 120V AC powered fans only Use only 14 or 12 copper wire connections IMPORTANT Read each step carefully and perform in sequence The CONTROL will not work or will become damaged if wires a...

Страница 16: ...t am ricain et international en instance Electrical Input 120 volts 60Hz Entr e lectrique 120 volts 60 Hz Maximum Fan Load 3 Amps Charge maximale du ventilateur 3 A Must Be Mounted Inside A Code Appro...

Страница 17: ...th the condensation humidity sensitivity set to average levels and the countdown timer set to 30 minutes To change the settings remove the TIMER AND SENSOR SETTINGS cover by taking off the face plate...

Страница 18: ...o the right an hour at a time Or if you feel the factory setting turns your fan on too quickly turn the dial to the left an hour at a time until the desired sensitivity level is reached Testing The Co...

Страница 19: ...room and not the drafts in the walls around edges punch outs wire access vent grooves Example Wall enclosures vary in design seal any openings found apply caulking in these types of areas Frequently...

Страница 20: ...hy the fan won t work Be safe consult a qualified licensed electrician Control Q I only have two black wires how do I properly connect the CONTROL A One of those wires is incoming power and one is pow...

Страница 21: ...r bath this is typically 25 35 minutes The manual timer setting does not change the drying time It is important that your room is properly dried The manual timer is for smell removal time only Q I los...

Страница 22: ...GTR s obligation to repair or replace at GTR s option shall be the purchaser s sole and exclusive remedy under this warranty GTR shall not be liable for incidental consequential or special damages ar...