Dewhot | Gas geyser manual

Read these instructions carefully before operating the 

gas geyser and familiarize yourself with the appliance 

before connecting it to the gas cylinder.  Keep these 

instructions for future reference. 

This appliance is manufactured to operate on LPG 

only. Do not tamper or modify the appliance.

If you smell gas

1.  Turn off the gas supply at the bottle
2.  Extinguish all naked flames
3.  Do not operate any electrical 

appliances

4.  Ventilate the area
5.  Check for leaks as described in this 

manual

6.  If gas smell persists, contact your 

dealer or gas supplier immediately

Burn-back 

In the event of a burn-back, where the 
flame burns back to the jet, immediately 
turn the gas supply off at the gas cylinder.  
After ensuring the flame is extinguished, 
wait for I minute and then reignite the 
appliance as per normal.  Should the 

appliance burn back again, close the gas 
cylinder and call a registered LPG installer.  
Do not use the appliance again until the 
installer has confirmed that it is safe to do 
so. 

Gas-pressure regulator 

This appliance requires an operating 
pressure of 2,8 kpa.  Only install a LPG 
regulator that complies with the SANS 1237 
requirements.

Guarantee

Should you to want to make a guarantee 
claim, you will need to supply your invoice 
and Certificate of Compliance (COC)

Important

Содержание LPDH 5

Страница 1: ...5L Flueless Low Pressure...

Страница 2: ...your dealer or gas supplier immediately Burn back In the event of a burn back where the flame burns back to the jet immediately turn the gas supply off at the gas cylinder After ensuring the flame is...

Страница 3: ...nd safety briefing Before you sign off the installation make sure you also receive your certificate of compliance COC Installer This appliance may only be installed by a LPG Installer registered with...

Страница 4: ...supply pressure of 0 015MPA This indicates that it is suitable for low water pressure applications Anti freeze protection The unit will automatically release a small amount of water to stop it from f...

Страница 5: ...ser manual Parts Diagram Oxygen Depletion Sensor ODS Flame Out Sensor Control Dial Gas Valve Battery Box Gas Inlet Heat Exchanger Burner Water Flow Sensor Thermostat Ignition Controller Water Inlet Va...

Страница 6: ...Warning 1 The gas geyser must be installed in a well ventilated place While Operating the gas geyser consumes a lot of oxygen so air inlet vents are required to match specification in table above Air...

Страница 7: ...les in the new pipe do not enter the gas geyser Hot Water Supply Pipe The hot water outlet joint is a standard half inch 15mm male plumbing fitting The hot water outlet pipe should be connected using...

Страница 8: ...so try two or three times 5 By closing the water inlet or outlet valve the gas heater will stop working If needed again just re open the water inlet valve or water outlet valve Please note that the t...

Страница 9: ...e premises for extended periods turn off your gas supply The body of the gas geyser can get very hot so please don t touch any part of the gas geyser except for the switches Do not put any foreign obj...

Страница 10: ...m drain holes in the battery box lid to stop any moisture build up in the future The geyser has new batteries and the water is flowing through the geyser but does not ignite properly Disconnect the in...

Страница 11: ...he solenoids can be faulty replace one at a time The unit fires over again for its 10 second cycle however the geyser does not ignite and you cannot hear the CLACK of the solenoids Disconnect the gas...

Страница 12: ...ularly clean the surface of the gas geyser body to remove dirt or dust using a neutral detergent 3 Do not use a a strong detergent like benzene or gasoline to clean the plastic parts and printed surfa...