Operating warnings

•  Don’t use the gas geyser in a sealed 

room or room with no air circulation. 

•  During operation, if you find there 

is a gas leak, turn off the gas valve 
immediately. If the room is full of gas, 
you must turn off the power switch. 
To avoid an explosion do not use 
the gas geyser and call your installer 
immediately to determine the fault. 

•  When leaving the premises for 

extended periods, turn off your gas 
supply.

•  The body of the gas geyser can get very 

hot, so please don’t touch any part of 
the gas geyser, except for the switches

•  Do not put any foreign objects in the 

exhaust port, air inlet or on top of 
the gas geyser to avoid incomplete 
combustion which results in posioning.

•  Should you notice a yellow flame which 

indicates abnormal combustion you 

should close the gas valve right away 
and then contact the installer.

•  Before outdoor temperatures reach 

below zero degrees make sure the 
remaining water is emptied out of the 
gas geyser to avoid it freezing.

Содержание LPDH 5

Страница 1: ...5L Flueless Low Pressure...

Страница 2: ...your dealer or gas supplier immediately Burn back In the event of a burn back where the flame burns back to the jet immediately turn the gas supply off at the gas cylinder After ensuring the flame is...

Страница 3: ...nd safety briefing Before you sign off the installation make sure you also receive your certificate of compliance COC Installer This appliance may only be installed by a LPG Installer registered with...

Страница 4: ...supply pressure of 0 015MPA This indicates that it is suitable for low water pressure applications Anti freeze protection The unit will automatically release a small amount of water to stop it from f...

Страница 5: ...ser manual Parts Diagram Oxygen Depletion Sensor ODS Flame Out Sensor Control Dial Gas Valve Battery Box Gas Inlet Heat Exchanger Burner Water Flow Sensor Thermostat Ignition Controller Water Inlet Va...

Страница 6: ...Warning 1 The gas geyser must be installed in a well ventilated place While Operating the gas geyser consumes a lot of oxygen so air inlet vents are required to match specification in table above Air...

Страница 7: ...les in the new pipe do not enter the gas geyser Hot Water Supply Pipe The hot water outlet joint is a standard half inch 15mm male plumbing fitting The hot water outlet pipe should be connected using...

Страница 8: ...so try two or three times 5 By closing the water inlet or outlet valve the gas heater will stop working If needed again just re open the water inlet valve or water outlet valve Please note that the t...

Страница 9: ...e premises for extended periods turn off your gas supply The body of the gas geyser can get very hot so please don t touch any part of the gas geyser except for the switches Do not put any foreign obj...

Страница 10: ...m drain holes in the battery box lid to stop any moisture build up in the future The geyser has new batteries and the water is flowing through the geyser but does not ignite properly Disconnect the in...

Страница 11: ...he solenoids can be faulty replace one at a time The unit fires over again for its 10 second cycle however the geyser does not ignite and you cannot hear the CLACK of the solenoids Disconnect the gas...

Страница 12: ...ularly clean the surface of the gas geyser body to remove dirt or dust using a neutral detergent 3 Do not use a a strong detergent like benzene or gasoline to clean the plastic parts and printed surfa...

Отзывы: