background image

7.

Type Plate and Seal

Each drive component carries a type plate giving the exact designation, item number
and technical specifications (for explanation see following figure as an example).

In order to guarantee the safety of
DEWERT products, a seal is attached
to all DEWERTproducts. Opening the
product damages the seal, thereby
indicating that the drive system has
been altered or tampered with. The
drive may only be opened by
specialist personnel holding the
qualifications as described on page 3.

17

Graphical Symbols

Conformity marks

Protection classification II

Application part of Type B

Protection category

Do not dispose of with the normal

household waste!

Dual system

Use in dry rooms only

I 66

P

DEWERT

A Phoenix Mecano Company

230V

50Hz

max. 1,6A

AB (Intermit.Operation) 2min / 18min
Baujahr (Prod.Date): 05/01
Seriennr.(Serial-No.): ABCD 123456

MCL CARE

nnnnn

I 66

P

Type designation

Item number

primary voltage

Application Range

Intermittent duty
2 minutes/ 18 minutes

DEWERT-Logo

max. primary current

Содержание MCL

Страница 1: ...Issue 06 2005 Installation Instructions for the Manufacturer of the End Product Drive Control Unit MCL CARE L CARE HOSP...

Страница 2: ...Instructions the drive control units are described under the code designation In doing so you can prevent mistakes being made in installing or connecting the system which could result in to the drive...

Страница 3: ...rmed by a This being the case you should never carry out this work unless you are a or Conformity according to EC Directives The drive control system is supplied ex factory as a machine in accordance...

Страница 4: ...of the mains connection lead should be carried out at short term intervals and in particular each time it has been subjected to a mechanical load If the mains connection lead of the drive control uni...

Страница 5: ...switch Blocking devices Battery AG7 Functions CARE L CARE HOSP MEGAMAT MEGAMAT MEGAMAT MULTIMAT B23 MULTIMAT B23 MULTIMAT B23 MEGAMAT P MEGAMAT P MEGAMAT P MEGAMAT 2 MEGAMAT 2 MEGAMAT 2 MEDIX CARE ME...

Страница 6: ...re Length x width x height of the control system 175 x 139 x 90 mm Weight approx 2 2 kg Room temperature from 10 to 40 C Rel humidity from 30 to 75 Barometric pressure From 700 hPa to 1060 hPa 1 2 Dim...

Страница 7: ...battery backup system can also be connected optional If ordered the optional battery backup system is supplied ex factory as an individual unit i e not connected The connection diagram for the batter...

Страница 8: ...en the bed is being First connect the as shown see page 18 Make sure that any sockets not being used are sealed off with If connecting an e g for emergency adjustment fasten this to the application us...

Страница 9: ...ication plug s pull out safeguard 1 earthing connection fitting option 1 fitting option 2 Caution For your own safety For battery powered drive systems it is not sufficient to simply pull out the main...

Страница 10: ...ol element indicates that a button is pressed With the CARE HOSP versions it signals in addition Version CARE HOSP 10 If you have acquired the drive control unit with a please note following Charge th...

Страница 11: ...lways lights up when power is being supplied to the unit mains or battery backup system if included The display serves in addition as an indicator for the charge status of the battery backup system if...

Страница 12: ...drive should be immobilized Note keep the handset away from and 1mT The integral blocking device can be activated or deactivated Further information on the function of the blocking device can be found...

Страница 13: ...eatures the same pictographs as on the handset i e the depicted function is blocked by the blocking switch Blocking is symbolized by a closed shackle lock Furthermore the can include adjustment button...

Страница 14: ...pervisor allows the bed to be adjusted as well as the adjustment functions to be blocked The Supervisor has been designed as a two hand control thereby making it impossible to actuate adjustment inadv...

Страница 15: ...doing so check whether the function LED on the handset lights up and listen out for the acoustic signal Check the function of the blocking device as described on pages 12 to 14 to ensure its readines...

Страница 16: ...onding programs offered by DEWERT After correctly changing the mains connection lead check for safety and proper function Service shaft The service shaft allows you to easily replace damaged mains cab...

Страница 17: ...ive may only be opened by specialist personnel holding the qualifications as described on page 3 17 Graphical Symbols Conformity marks Protection classification II Application part of Type B Protectio...

Страница 18: ...unit e g AG7 DEWERT foot switch e g FP2 FP4 Pos Part designation Description 1 2 3 6 7 1 1 or or or This can otherwise result in damage to the drive control unit DEWERT bridge plug bridging the block...

Страница 19: ...le if necessary restoring contact Permanent or longer sounding warning signal CARE HOSP only Control unit is defective Contact your supplier dealer Function LED in the Handset does not light up when k...

Страница 20: ...onents cables metal plastic etc This system should be disposed of in accordance with the environmental regulations applicable in the respective country Information on this subject can also be obtained...

Страница 21: ...is machine may not be put into operation until conformity with the above Directive of the entire machine into which it is to be installed has been declared Partially applied harmonized standards of Ma...

Страница 22: ...d in the Installation Instructions as well as the designated use in other words which change the drive system in a considerable way make this Declaration of Conformity null and void Management DEWERT...

Страница 23: ...ive temperatures EN60601 1 main section 9 Operation outside the requirements and faults cases EN60601 1 main section 10 Constructional requirements EN60601 1 section 56 8 Power supply indicator option...

Страница 24: ...ing device supervisor or IPROXX SE SE EN60601 2 38 section 22 4 101 Control unit with keypad EN60601 2 38 section 36 Electromagnetic compatibility EN60601 2 38 section 52 4 Unintentional movement EN60...

Страница 25: ...25 Notes...

Страница 26: ...MCL 26 Notes...

Страница 27: ...27 Notes...

Страница 28: ...DEWERT Antriebs und Systemtechnik Weststra e 1 32278 Kirchlengern Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewert de Info dewert de GmbH ID no 49343...

Отзывы: