2. Place canister upside down position until dry. DO
NOT use wet canister for dry pick up.
3. Place vacuum head on a level surface until dry.
4. Reinstall filters when vacuum head is dry. See Filters
under Maintenance.
5. When canister is dry place the vacuum head
onto the canister and secure it by closing the
canister latches .
Shut Down/Transportation (Fig. A)
1. Turn on/off control switch to the OFF position.
2. Unplug the unit.
3. Store the power cord wrapping it around the top
handle/cord wrap as shown.
4. When transporting in vehicles, secure the machine.
MAINTENANCE
Your D
E
WALT appliance has been designed to operate
overa long period of time with a minimum of
maintenance.Continuous satisfactory operation
depends upon proper appliance care and regular
cleaning.
WARNING:
To reduce the risk of injury,
turn appliance off and disconnect
appliance from power source before
installing and removing accessories
,
before
adjusting or changing set-ups or when
making repairs.
An accidental start-up can cause
injury.
WARNING:
For user servicing, the machine must
be dismantled, cleaned and serviced, as far as is
reasonably practicable, without causing risk to the
maintenance staff and others. Suitable precautions
include, decontamination before dismantling, provision
for local filtered exhaust ventilation where the machine
is dismantled, cleaning of the maintenance area and
suitable personal protection.
• The manufacturer, or an instructed person, shall
perform a technical inspection at least annually,
consisting of, for example, inspection of the filter for
damage, air tightness of the machine and proper
function of the control mechanism.
• When carrying out service or repair operations, all
contaminated items which cannot be satisfactorily
cleaned, are to be disposed of; such items shall be
disposed of in impervious bags in accordance with
any current regulation for the disposal of such waste.
• For dust extractors it is necessary to provide for an
adequate air change rate L in the room if the exhaust
air is returned to the room.
(
NOTE:
Reference to National Regulations is
necessary.)
To Remove Filters
1. Turn on/off/tool control switch to the OFF
position ( O ) and unplug cord from outlet.
2. Release canister latches and remove vacuum
head . from canister. Place vacuum head on a
level surface upside down.
3. Turn each filter counterclockwise by gripping it on
the plastic end cover as shown, and carefully remove
from head, ensuring debris does not fall into mounting
hole.
NOTE:
Use care to not damage filter material.
4. If the bottom side of the vacuum head needs to
be cleaned, use a cloth dampened with water and
mild soap and allow it to dry. Dispose of cloth in an
appropriate container.
5. Inspect filters for wear, tears or other damage.
NOTE:
If there is any doubt on the condition of the
filters they MUST be replaced. DO NOT continue use
if filters are damaged.
WARNING:
Never use compressed air or a brush
to clean filters, otherwise damage to the filter membrane
will occur which will allow dust to pass through the filter.
If needed, gently tap against a hard surface or rinse with
room temperature water and let air dry. Cleaning of the
filters is typically unnecessary, even if the filter is covered
with dust. The automatic filter cleaning system will
maintain maximum performance and continue to function.
If visual damage to the filter membrane exists, replace
filters. Filters typically last between six and twelve months
depending on use and care.
To Install Filters
1. Ensure filter seal is in place and is secure.
2. Line up filter threads to vacuum head threads and
using moderate force, turn filter clockwise until tight.
NOTE: Use care to not damage filter material.
3. Place the vacuum head onto the container and
secure it by closing the canister latches .
Filter (Fig. A, H, I)
Filter care
The filters included with this vacuum are long life filters.
To be effective in minimizing dust recirculation, the filters
MUST be installed correctly and in good condition.
WARNING:
Appropriate personal protective
equipment like dust mask and gloves should be used
while handling the filters.
15
16
4
5
Empty The Tank (Fig. J)
WARNING:
To reduce the risk of injury from
accidental starting, unplug power cord before emptying
the dust tank.
1. Remove the power head assembly of the wet/dry
vac bypulling outward on the lid clips located on each
side of the vac. Lift off the power head assembly.
2. Dump the tank contents into the proper waste
disposal container.
BLOWING OPERATION
WARNING:
To avoid injury to bystanders, keep
them clear of blowing debris.
CAUTION:
Wear a dust mask if blowing creates
dust which might be inhaled.
CAUTION:
To reduce the risk of hearing loss, wear
ear protectors when using the vac/blower for extended
hours or when using it in a noisy area.
Содержание DXV23P