3
English
CONTENTS
WARNINGS
2
HEATER SPECIFICATIONS
3
OPERATING & SAFETY PRECAUTIONS
4
OPERATING INSTRUCTIONS
4
MAINTENANCE
5
TROUBLESHOOTING
7
EXPLODED VIEW AND PARTS LIST
8
WIRING DIAGRAM
10
WARRANTY
11
Heater Specifications
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing injury or loss of
life.
- Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
- Service must be performed by a qualified service agency.
WARNING
Not suitable for use on wood floors or other combustible materials. When
used the heater should rest on a suitable insulating material at least 1 inch
thick and extending 3 feet or more beyond the heater in all directions.
CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8
(Jet A Fuel)
MODEL NO.: ............................................................................. DXH70KTFRHC
BTU/hr: .......................................................................................70,000 BTU/hr
(20.5 kW)
CONSUMPTION RATE: ..................................................................0.52 GAL/hr
(1.97 L/hr)
TANK CAPACITY: ......................................................................2.77 GALLONS
(10.5 L)
RUN TIME: ....................................................................................... 5.34 hours
ELECTRICAL INPUT: .................................................................... 115 V, 60 HZ
ASSEMBLED DIMENSIONS: ...........................................13.25” X 25” X 22.25”
(33.6 cm X 63.5 cm X 56.5 cm)
DRY WEIGHT: ........................................................................40 lbs. (18.14 kg)
FULL WEIGHT: .........................................................................44 lbs. (20.0 kg)
APPROXIMATE HEATING AREA: ............................ 1750 SQ. FT (162.5 SQ. m)
THERMOSTAT RANGE: .................................... 41°F to 99°F ( 5 °C to 37.2 °C )
DEFAULT THERMOSTAT SETTING: .............................................68 °F ( 20 °C )
Clearance To Combustibles
From Outlet From Sides
From Top
From Rear
8 ft (2.44m)
3ft (0.9 m)
3ft (0.9 m)
3ft (0.9 m)
To
p
Floor
Rear
Sides
Outlet
3 ft (0.91 m)
3 ft (0.91 m)