Maintenance
1. The heater should be inspected before each use, and at least annually by a
qualified person.
2. Before each use, check the soft “O” ring seat at the bullnose of the POL fitting.
If the “O” ring is cut, scuffed, or otherwise damaged, replace it with part number
F273786.
3. Turn off the gas at the LP-gas supply cylinder(s) when the heater is not in use.
4. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
5. When the heater is to be stored indoors, the connection between the LP-gas
supply cylinder(s) and the heater must be disconnected and the cylinder(s)
removed from the heater and stored out of doors and in accordance with Chapter
5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI/
NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
Stopping Heater
1. Securely close valve on the propane cylinder.
2. Continue to operate heater until all fuel in the hose has burned.
3. Unplug the power cord.
CAUTION:
Always shut off fuel supply before disconnecting electrical power.
RESTART AFTER SAFETY SHUTDOWN
1. Securely close valve at propane cylinder. Unplug power cord.
2. Wait 5 minutes.
3. Restart following “START” procedure.
Servicing
A hazardous condition may result if a heater is used that has been modified or is not
functioning properly. When the heater is working properly:
* The flame is contained within the heater.
* The flame is essentially blue with perhaps some yellow tipping.
* There is no strong disagreeable odor, eye burning or other physical discomfort.
* There is no smoke or soot internal or external to the heater.
* There are no unplanned or unexplained shut downs of the heater.
The parts lists and exploded view show the heater as it was constructed. Do not
use a heater which is different from that shown. In this regard, use only the hose,
regulator and cylinder connection fitting (called a POL fitting) supplied with the
heater.
IMPORTANT
Match the color stripe on the hang tag attached to the hose
assembly with the color on the label located near the propane inlet fitting on the
heater. Do not use alternates. For this heater, the regulator comes factory set as
shown in "specifications". If there is any uncertainty about the regulator setting, have
it checked.
A heater which is not working right must be repaired, but only by a trained,
experienced service person.
In-warranty products will be repaired with no charge for either parts or labor. Please
include a brief statement indicating date, place of purchase, the nature of the
problem and proof of purchase.
Out-of-warrranty products will be repaired with a charge for parts and labor.
Size and Capacity of Propane Cylinders Required
The charts below show the approximate size of the cylinder required for these
heaters. To use the chart:
1. Select the lowest air temperature expected (at the bottom of the chart).
2. Move straight up to time of operation desired (left side of chart).
3. Read the cylinder size required.
All heaters should have: full cylinders, good air circulation, no frost on cylinders
TIMe (Hrs.)
TIME (HRS.)
AMBIENT TEMPERATURE °F ( °C)
BTU’S PER HOUR REQUIRED
Cubic feet
of space
to be
heated
Temperature Rise Required ( °F)
20 °
30 °
40 °
50 °
5,000
14,000
20,000
27,999
34,000
7,000
19,000
28,000
38,000
47,000
10,000
27,000
40,000
54,000
67,000
15,000
40,000
60,000
80,000
100,000
20,000
54,000
80,000
107,000
133,000
30,000
80,000
120,000
160,000
200,000
50,000
133,000
200,000
266,000
333,000