13
Voltage
Amperes
Cable rating (Amperes)
230
0 - 2.0
6
6
6
6
6
6
2.1 - 3.4
6
6
6
6
6
6
3.5 - 5.0
6
6
6
6
10
15
5.1 - 7.0
10
10
10
10
15
15
7.1 - 12.0
15
15
15
15
20
20
12.1 - 20.0
20
20
20
20
25
-
Assembly and adjustment
Prior to assembly and adjustment always
unplug the tool.
Mounting a cutter (fig. B)
• Insert the locking pin supplied into the hole (4)
to lock the spindle.
• Thread an M12 cutter onto the spindle.
For M8 cutters, use a bit holder (DE6281).
• Remove the pin.
Instructions for use
Always observe the safety instructions
and applicable regulations.
Prior to operation:
• Make sure that the tool is well fixed.
• Check that the spindle is not locked.
• Check that the cutter is correctly installed on
the spindle.
Switching on and off (fig. A)
• To switch the tool on, set the switch to
the
I
position.
• To switch the tool off, set the switch to
the
0
position.
Consult your dealer for further information on the
appropriate accessories.
Maintenance
Your D
E
WALT Power Tool has been designed to
operate over a long period of time with a minimum
of maintenance. Continuous satisfactory operation
depends upon proper tool care and regular cleaning.
Lubrication
Your power tool requires no additional lubrication.
Cleaning
Keep the ventilation slots clear and regularly clean
the housing with a soft cloth.
Unwanted tools and the environment
Take your tool to an authorized D
E
WALT repair
agent where it will be disposed of in an