17
E
• If using X-axis slope, the X-axis LED (Figure
A
15
) will light,
or if using Y-axis slope, the Y-axis LED (Figure
A
14
) will light
instead.
7.
When in
Slope Mode
, press
or
to tilt the laser head up and
down (adjust the elevation of the laser beam).
• Each quick press of or will move the slope by 0.01º (1/16”
@ 30ft. or 1.6mm @ 10m).
• If you press and hold or between 2 sec - 10 sec, the
slope will move from 0.01º/sec to 0.2º/sec.
• If you press and hold
or longer than 10 sec, the slope
will move 0.2º/sec.
8.
To turn off the laser unit, press and hold the power button
for 3
secs.
9.
BEFORE using the laser for your first project
, follow the
instructions for Checking the Calibration.
NOTE:
When you press the
Slope Mode
button again, the laser
will return to self-level mode.
Checking the Calibration
Field calibration checks should be done frequently. This section
provides instructions for performing simple field calibration checks
of your
D
e
WALT
Rotary Laser. Field calibration checks do not
calibrate the laser. That is, these calibration checks do not correct
errors in the leveling or plumb capability of the laser. Instead, these
checks indicate whether or not the laser is providing a correct level
and plumb line. These checks cannot take the place of professional
calibration performed by a
D
e
WALT
service center.
Level Calibration Check (X-axis)
1.
Position a tripod securely on the floor between two walls that are at
least 50 feet apart. The exact location of the tripod is not critical.
2.
Make sure that the top of the tripod is roughly level.
• The laser will self-level only if the top of the tripod is within ±
5˚ of level.
• If the laser is set up too far out of level, it will beep when it
reaches the limit of its leveling range. No damage will be done
to the laser, but it will not operate in an “out of level” condition.
3.
Attach a tripod adapter (Figure
G
1
) to the laser unit. The
adapter may be assembled to the bottom for level mode (Figure
G
2
) or to the side for plumb (vertical) mode (Figure
I
3
).
4.
Place the laser with the attached adapter on the tripod and
screw the threaded knob on the tripod into the female thread on
the tripod adapter.
5.
Position the laser unit on the tripod so that the laser’s X-axis
points directly toward one of the walls (Figure
M
1
).
6.
Turn the laser unit on and allow it to self-level.
7.
Where the beam appears on the left wall, mark point
A
, and where
the beam appears on the right wall mark point
B
.
8.
Turn the laser unit 180º so that the X-axis points directly toward
the opposite wall (Figure
M
2
).
9.
Allow the laser unit to self-level.
10.
Where the beam appears on the left wall, mark point
AA
, and
where the beam appears on the right wall mark point
BB.
11.
Calculate the
Total Error
using the following equation:
Total Error = (AA-A) - (BB-B)
12.
If your
Total Error
measurement is greater than the
Allowable
Error
for the corresponding
Distance Between Walls
in the
following table, the laser must be serviced at an authorized
service center.
L (Distance Between
Walls)
Allowable Error
40
′
(15m)
3/64” (1.5mm)
50
′
(20m)
1/16” (2mm)
70
′
(25m)
3/32” (2.5mm)
100’ (30m)
1/8” (3mm)
Содержание DW080LGS
Страница 1: ...E PT ES F www DEWALT com Self Leveling Rotary Laser DW080LRS DW080LGS ...
Страница 2: ...8 Figures 2 A B C 10 11 12 13 14 15 16 17 18 19 1 2 6 7 4 3 5 7 6 4 3 2 5 1 8 9 ...
Страница 3: ...3 3V CR2430 D DEWALT 20V 2Ah USB F E 5 7 6 6 8 DW0743GS 3 1 4 2 9 10 13 11 12 7 7 14 ...
Страница 4: ...Figures 4 4 5 6 4 DW0743GS 5 8 11 1 2 3 G H 1 2 5 8 11 I 1 2 3 2 ...
Страница 5: ...5 J DW0743GS 50 100 1000 100 1 2 3 ...
Страница 6: ...Figures 6 K 1 2 ...
Страница 7: ...7 L ...
Страница 8: ...Figures 8 L X AA BB M L X A B ...
Страница 9: ...9 L Y A B L Y AA BB N ...
Страница 10: ...Figures 10 P O ...
Страница 11: ...11 Q 2 1 4 3 5 6 7 8 4 2 3 1 8 9 S R T ...
Страница 81: ...Notes ...
Страница 82: ... 2019 DeWALT 701 East Joppa Road Towson Maryland 21286 N639381 April 2019 ...