8
MINIMUM GAUGE FOR CORD SETS
For Cable length (m):
7.5 15 25 30 45 60
Use Cable with minimum rating (Amperes)
Tool Amperes
0 - 3.4
7.5
7.5
7.5
7.5
7.5 7.5
3.5 - 5.0
7.5
7.5
7.5
7.5
10
15
5.1 - 7.0
10
10
10
10
15
15
7.1 - 12.0
15
15
15
15
20
20
12.1 - 20.0
20
20
20
20
25
–
•
Do not place any object on top of charger or place the charger on a soft
surface that might block the ventilation slots and result in excessive internal
heat.
Place the charger in a position away from any heat source. The charger is
ventilated through slots in the top and the bottom of the housing.
•
Do not operate charger with damaged cord or plug
— have them replaced
immediately.
•
Do not operate charger if it has received a sharp blow, been dropped, or
otherwise damaged in any way.
Take it to an authorized service center.
•
Do not disassemble charger; take it to an authorized service center when
service or repair is required.
Incorrect reassembly may result in a risk of
electric shock, electrocution or fire.
•
Disconnect the charger from the outlet before attempting any cleaning. This
will reduce the risk of electric shock.
Removing the battery pack will not reduce
this risk.
•
NEVER
attempt to connect 2 chargers together.
•
The charger is designed to operate on standard household electrical power
(230 Volts). Do not attempt to use it on any other voltage.
This does not apply
to the vehicular charger.
Using Automatic Tune-Up™ Mode
The automatic Tune-Up™ Mode equalizes or balances the individual cells in the
battery pack allowing it to function at peak capacity. Battery packs should be tuned up
weekly or after 10 charge/discharge cycles or whenever the pack no longer delivers
the same amount of work. To use the automatic Tune-Up™, place the battery pack
in the charger and leave it for at least 8 hours. The charger will cycle through the
following modes.
1. The red light will blink continuously indicating that the 1-hour charge cycle has
started.
2. When the 1-hour charge cycle is complete, the light will stay on continuously and
will no longer blink. This indicates that the pack is fully charged and can be used
at this time.
3. If the pack is left in the charger after the initial 1-hour charge, the charger will
begin the Automatic Tune-Up mode. This mode continues up to 8 hours or until
the individual cells in the battery pack are equalized. The battery pack is ready for
use and can be removed at any time during the Tune-Up mode.
4. Once the Automatic Tune Up mode is complete, the charger will begin a
maintenance charge; the red indicator will remain lit.
SAVE THESE INSTRUCTIONS FOR FUTURE USE
Chargers
Your tool uses a D
E
WALT Charger. Your battery can be charged in D
E
WALT 1 Hour
Chargers, 15 Minute Chargers or Vehicular 12 volt charger. Be sure to read all safety
instructions before using your charger. Consult the chart on the back cover of this
manual for compatibility of chargers and battery packs.
FIG. 2
15 MINUTE CHARGER
1 HOUR CHARGER