13 Notes: 

Содержание ARADA Farringdon Eco Series

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK695 SPECIFIC Rev 03 ISSUE DATE 09 11 2017 EN 13240 2011 A2 2004 Farringdon Eco Stove User Guide...

Страница 2: ...e of heating satisfaction Should you have any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on 44...

Страница 3: ...lid fuel 4 Before using your stove 5 Air inlet controls 5 1 Air inlet 5 1 1 Primary air control location 5 1 2 Primary air control 5 1 3 Secondary air control 5 1 4 Tertiary air 6 Lighting your stove...

Страница 4: ...Fire door handle riddle handle 8 How heat is delivered by your stove 8 1 Radiant heat 9 Care for your Arada stove 9 1 Adjusting the door hinges 9 2 Liners firebricks 9 3 Throat plate secondary throat...

Страница 5: ...Data Plate Grate Riddle Socket NOTE Both Sides Of The Stove Rear Flue Outlet NOTE Top Rear Flue Outlets Are Interchangeable Will Depend Upon Installation Fire Door Assembly Fire Door Handle Socket Fi...

Страница 6: ...Eco Stove User Guide Fuel Retainer Firebox Liners Sides Rear Flexifuel Grate Bars Fire Door Glass 1 2 Identifying parts terminology of your stove Internal Throat Plate Tertiary Outlet Ash Pan Locatio...

Страница 7: ...iquid fuels allowed Pure petroleum coke or Bituminous house coal must NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that the air inlet ve...

Страница 8: ...appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 Similarly in Northern Ireland appliances are exempted by publication...

Страница 9: ...n of tar and creosote which may in extreme cases run down the chimney in liquid form This will seriously damage both the chimney and the appliance and increase the risk of a chimney fire 3 2 Mineral S...

Страница 10: ...n building regulations have been undertaken by the installation fitter Consideration must be given for the need for extra ventilation if another heating source needing air is to be operated simultaneo...

Страница 11: ...direct air feed ducting depending upon the installation requirements NOTE DO NOT COVER OR PARTIALLY OB STRUCT THE AIR INLET OPENINGS FOR THE APPLIANCE 5 1 1 Primary air control location The primary ai...

Страница 12: ...it will go achieves the fully open position see figure 1 Sliding it to the left will shut down reduce the air as shown in figure 2 5 1 3 Secondary air control The secondary air control regulates the...

Страница 13: ...l will not fully close thus allowing a bleed of air to the fire box to reduce smoke emissions 5 1 4 Tertiary Air All Farringdon models have tertiary air supply that can be seen working during certain...

Страница 14: ...s a good supply of air coming from above the fuel For this reason we will use all the air inlets while igniting the stove but will then reduce this to air coming from the air wash system and over drau...

Страница 15: ...e bars The use of two or three fire lighters may assist in lighting the kindling 3 After the kindling has caught light you should almost close the fire door leading it ajar by about 10mm This will aid...

Страница 16: ...the cause of the fume emission has been identified and corrected 6 5 Refuelling on to a low fire bed If there is insufficient burning material in the fire bed to light a new fuel charge excessive smo...

Страница 17: ...ecution and fine 6 6 Typical burn for nominal output To perform the most efficient burn at the nominal rated output please consult the specification table at the rear of this manual Please note many f...

Страница 18: ...demonstrate the over heating of internal parts body paint which has turned dusty white is also indicative of such use 7 3 Chimney fires Used in the correct manner with the correct fuel and regular ma...

Страница 19: ...e stove pausing briefly when ajar so as to allow the fire to adjust to the increased air supply Locate the central handle on the ash pan with one hand Carefully withdraw the ash pan from the ash pit c...

Страница 20: ...ng rate open windows and allow the stove s fuel to burn out before closing the windows The probable cause is insufficient draw check flue ways and have the chimney tested for flue pressure 7 10 Door g...

Страница 21: ...lass and less intense the further you move away from the stove This radiated heat is delivered as infrared rays which heat the objects they strike It is then these objects such as the chimney breast h...

Страница 22: ...er plate Check repeat again if necessary 9 2 Liners firebricks The stoves liners also known as firebricks may become cracked after long periods of heavy use or after being knocked by the loading of fu...

Страница 23: ...into the firebox and it may fail completely leading to personal injury or a fire You should discontinue use of your stove until it has been repaired You can source replacement glass kits from www ara...

Страница 24: ...where you can discover more information about your stove and associated articles Arada Technical Support 01297 632052 technical aradastoves com Arada Stoves Support Site www aradastoves com support Co...

Страница 25: ...ch use The following guarantee periods shall apply in respect of the following Arada stoves Arada stoves come with a lifetime guarantee to the main body The external paint finish carries a one year gu...

Страница 26: ...ed by this guarantee Firebox linings Grate bars Fuel retainer Throat plate Gaskets Door glass Seals 9 The guarantee does not cover damage caused by storing or using the stove in a damp environment def...

Страница 27: ...in information about your legal rights from trading standards office s or a citizens advice bureau If you believe your appliance is not working correctly or it has broken down in the first instance pl...

Страница 28: ...mm 522 5 547 5 547 5 Depth From Back To Flue Centre mm 108 5 113 5 113 5 Flue Diameter mm Inch 127 5 152 6 152 6 Minimum Distance To Combustible Materials Single Walled Flue mm 350 Rear 500 Side 500 R...

Страница 29: ...Seasoned Hardwood 1 11 1 82 1 74 Mean CH Emission 13 O2 92 40 63 Mean NOx Emission 13 O2 79 97 75 DIN Plus Particulates 13 O2 13 27 13 Ideal Log Length Diameter mm 360 100 420 125 500 150 Nominal Heat...

Страница 30: ...Page 30 BK695 Farringdon Eco Stove User Guide 13 Notes...

Страница 31: ...BK695 Page 31 Farringdon Eco Stove User Guide 13 Notes...

Страница 32: ...K695 Farringdon Eco Stove User Guide All Arada Stoves are manufactured in the UK Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050...

Отзывы: