![Devon ARADA Farringdon Eco Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/devon/arada-farringdon-eco-series/arada-farringdon-eco-series_user-manual_2489717029.webp)
BK695
Page 29
Farringdon Eco Stove User Guide
TECHNICAL DATA
Farringdon Small
Eco
Farringdon Medium
Eco
Farringdon Large
Eco
Nominal Heat Output—Wood (Kw)
5
8.2
10.6
Efficiency Nett (%)
77.8
76.1
77
Mean Flue Gas Temperature (°C
261
293
337
Mean CO Emission @ 13% O2 (%)
0.11
0.06
0.08
Flue Mass Gas Flow (g/s)
5.1
8
8.5
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (Seasoned Hardwood)
1.11
1.82
1.74
Mean CH Emission @ 13% O2 (%)
92
40
63
Mean NOx Emission @ 13% O2 (%)
79
97
75
DIN Plus Particulates @ 13% O2 (%)
13
27
13
Ideal Log Length & Diameter (mm)
360 / 100
420 / 125
500 / 150
Nominal Heat Output—Solid fuel (Kw)
4.9
8.1
12.1
Efficiency Nett (%)
82.4
79.8
79.8
Mean Flue Gas Temperature (°C)
272
340
377
Mean CO Emission @ 13 % O2 (%)
0.06
0.03
0.04
Flue Mass Gas Flow (g/s)
3.5
5.5
7.2
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (MSF Maxibrite)
0.71
1.16
1.74
Mean CH Emission @ 13% O2 (%)
5
3
6
Mean NOx Emission @ 13% O2 (%)
79
128
66
DIN Plus Particulates @ 13% O2 (%)
5
7
8