background image

3 — ENG

RISK OF BURSTING

RISK OF

EXPLOSION OR FIRE

RISK OF

ELECTRICAL SHOCK

AIR TANK

THE FOLLOWING CONDITIONS COULD

 LEAD

TO A WEAKENING OF THE TANK, AND 

RESULT IN

A VIOLENT TANK EXPLOSION:

1.

FAILURE TO PROPERLY DRAIN

CONDENSED

  WATER FROM THE TANK,

CAUSING RUST AND THINNING OF THE
STEEL TANK.

2. 

MODIFICATIONS

 OR ATTEMPTED

REPAIRS 

TO THE TANK.

3. UNAUTHORIZED 

MODIFICATIONS TO THE

PRESSURE SWITCH, SAFETY VALVE, OR

ANY 

OTHER COMPONENTS WHICH

CONTROL

 TANK 

PRESSURE.

ATTACHMENTS  & ACCESSORIES

EXCEEDING THE PRESSURE RATING OF AIR
TOOLS,

 SPRAY GUNS, AIR OPERATED ACCES-

SORIES, TIRES AND OTHER INFLATABLES 

CAN

CAUSE THEM TO EXPLODE

 OR FLY APART, AND

COULD RESULT IN SERIOUS INJURY.

IT IS NORMAL FOR ELECTRICAL CONTACTS

WITHIN THE MOTOR AND PRESSURE SWITCH

TO SPARK.

IF

 ELECTRICAL 

SPARKS

 FROM COMPRESSOR

COME INTO CONTACT WITH FLAMMABLE
VAPORS, THEY MAY IGNITE, CAUSING FIRE OR
EXPLOSION.

RESTRICTING

 ANY OF THE 

COMPRESSOR

VENTILATION OPENINGS WILL CAUSE SERI-
OUS OVERHEATING AND COULD CAUSE FIRE.

YOUR 

AIR COMPRESSOR IS POWERED BY

ELECTRICITY.

  LIKE ANY OTHER ELECTRICALLY

POWERED DEVICE, 

IF IT IS NOT USED

PROPERLY IT MAY CAUSE ELECTRIC SHOCK.

DRAIN TANK DAILY OR AFTER EACH USE.

  IF

TANK DEVELOPS A LEAK, REPLACE IT
IMMEDIATELY WITH A NEW TANK OR NEW
COMPRESSOR OUTFIT.

NEVER

 DRILL INTO, WELD, OR 

MAKE ANY

MODIFICATIONS TO THE TANK

 OR ITS

ATTACHMENTS.

THE TANK IS DESIGNED TO WITHSTAND
SPECIFIC OPERATING PRESSURES.  

NEVER

MAKE ADJUSTMENTS OR PARTS SUBSTITU-
TIONS TO

 ALTER THE 

FACTORY SET

OPERATING 

PRESSURES.

FOLLOW THE EQUIPMENT MANUFACTURERS
RECOMMENDATION AND NEVER
EXCEED THE MAXIMUM ALLOWABLE PRES-
SURE RATING OF ATTACHMENTS.  

NEVER

USE COMPRESSOR TO INFLATE SMALL
LOW-PRESSURE OBJECTS SUCH AS
CHILDREN’S TOYS, FOOTBALLS,
BASKETBALLS. ETC.

ALWAYS 

OPERATE THE COMPRESSOR IN A

WELL VENTILATED 

AREA FREE OF COMBUS-

TIBLE MATERIALS, GASOLINE OR SOLVENT
VAPORS.

IF SPRAYING FLAMMABLE MATERIALS, 

LO-

CATE COMPRESSOR AT LEAST 20 FEET
AWAY FROM SPRAY AREA.

  AN ADDITIONAL

LENGTH OF HOSE MAY BE REQUIRED.

STORE FLAMMABLE MATERIALS IN A
SECURE LOCATION AWAY FROM COM-
PRESSOR.

NEVER PLACE OBJECTS AGAINST OR ON
TOP OF COMPRESSOR.  OPERATE COM-
PRESSOR

 IN AN OPEN AREA AT LEAST 

12

INCHES AWAY FROM 

ANY  WALL OR

OBSTRUCTION

 THAT WOULD RESTRICT THE

FLOW OF FRESH AIR TO THE VENTILATION
OPENINGS.

NEVER OPERATE THE COMPRESSOR OUT-
DOORS WHEN IT IS RAINING OR IN WET
CONDITIONS.

NEVER OPERATE COMPRESSOR WITH
COVER

 COMPONENTS 

REMOVED

 OR DAM-

AGED.

HAZARD

WHAT CAN HAPPEN

HOW TO PREVENT IT

•  SAVE THESE INSTRUCTIONS •

IMPORTANT SAFETY INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS IN-
JURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING IN-
STRUCTIONS BEFORE USING THIS EQUIPMENT.

CONTINUE NEXT PAGE *

Содержание MG7-OFTWIN

Страница 1: ...E 12 13 TABLE OF CONTENTS SAFETY GUIDELINES DEFINITIONS Information for preventing damage to equipment This manual contains information that is important for you to know and understand This informatio...

Страница 2: ...er installation and start up cost ANY INCIDENTAL INDIRECT OR CONSEQUENTIAL LOSS DAMAGE OR EXPENSE THAT MAY RESULT FROM ANY DEFECT FAILURE OR MALFUNCTION OF THE PRODUCT Some states do not allow the exc...

Страница 3: ...ER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTITU TIONS TO ALTER THE F...

Страница 4: ...RMED BY AUTHORIZED SERVICE CEN TER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELECTR...

Страница 5: ...ociety of Mechanical Engineers made tested inspectedandregisteredtomeetthestandardsofASME California Code Unit may comply with California Code 462 L 2 M 2 Specification modellabelisonthesideofthetanko...

Страница 6: ...rom a higher to a lower setting first reduce to some pressure less than that desired then bring up to the desired pressure Depending on the air requirements of eachparticularaccessory theoutletregulat...

Страница 7: ...an extension cord must be used do not use with any permanently mounted air compressor use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the p...

Страница 8: ...hecompressorisproperlygrounded have the installation checked by a qualified electrician GROUNDING INSTRUCTION Portable Units RISK OF ELECTRICAL SHOCK In the event of a shortcircuit groundingreducesthe...

Страница 9: ...to OFF and the air regulator or globe valve is closed 2 Attach hose and accessories TOO MUCH AIR PRESSURE CAUSES A HAZARD OUSRISKOFBURSTING CHECKTHEMANUFAC TURER SMAXIMUMPRESSURERATINGFORAIR TOOLS AND...

Страница 10: ...w the check valve turn counterclockwise using a socketwrench 6 Check that the valve disc moves freely inside the check valveandthatthespringholdsthediscintheupper closed position The check valve may b...

Страница 11: ...oosely around the compressor handle 3 Store the air compressor in a clean and dry location Before you store the air compressor make sure you do the following 1 Review the Maintenance and Operating Pro...

Страница 12: ...you need a larger compressor Clean or replace air intake filter Do not operate the air compressor with the filter removed See page 8 Check and replace if required Remove and clean or replace Tighten...

Страница 13: ...and terminal box area Contact an Authorized Warranty Service Center for inspection or replacement if necessary Have checked by an Authorized Warranty Service Center Do not operate the compressor in th...

Страница 14: ...14 ENG SERVICE NOTES NOTAS DE SERVICIO NOTES SUR LE SERVICE...

Страница 15: ...15 ENG SERVICE NOTES NOTAS DE SERVICIO NOTES SUR LE SERVICE...

Страница 16: ...DeVilbiss Air Power Company 213 Industrial Drive Jackson TN 38301 9615 GENERAL MANUAL FOR PERMANENTLY LUBRICATED TWIN CYLINDER AIR COMPRESSORS SERVICE NOTES...