background image

12 — ENG

PROBLEM

CAUSE

Move the pressure switch lever to the “OFF” posi-
tion.  If the outfit doesn’t shut off, unplug. If the
electrical contacts are welded together, replace the
pressure switch.

Contact an authorized service center to check and
replace pressure switch.

Tighten fittings where air can be heard escaping.
Check fittings with soapy water solution. 

DO NOT

OVER-TIGHTEN.

A defective check valve results in a constant air leak
at the pressure release valve when there is pressure
in the tank and the compressor is shut off.  Drain tank
then remove and clean or replace check valve.  

DO

NOT OVER-TIGHTEN.

Remove and replace the release valve.

A defective check valve results in a constant air leak
at the pressure release valve when there is pressure
in the tank and the compressor is shut off.  Drain tank
then remove and clean or replace check valve.  

DO

NOT OVER-TIGHTEN.

Torque head screws to 8 ft. lbs. If this does not stop
leak, replace o-ring.

If there is an excessive amount of pressure drop
when the accessory is used, adjust the regulator
following the instructions on page 6.

NOTE:

Adjust the regulated pressure under flow
conditions (while accessory is being  used).

Operate safety valve manually by pulling on ring.  If
valve still leaks, it should be replaced.

Remove and clean, or replace.

Decrease amount of air usage.

Check the accessory air requirement.  If it is higher
than the SCFM or pressure supplied by your air
compressor, you need a larger compressor.

Clean or replace air intake filter. Do not operate the
air compressor with the filter removed. See page 8.

Check and replace if required.

Remove and clean, or replace.

Tighten fittings.  (See Air Leaks Section of Trou-
bleshooting Guide.)

PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES.  PER-
SONAL INJURY MAY OCCUR.  PRIOR TO ATTEMPTING ANY REPAIRS, DISCONNECT POWER SOURCE FROM THE
COMPRESSOR AND BLEED OFF TANK AIR PRESSURE.

CORRECTION

Pressure switch does not shut off
motor when compressor reaches
“cut-out” pressure.

Pressure switch “cut-out” too high.

Tube fittings are not tight enough.

Defective or dirty check valve.

Defective pressure switch release valve.

Defective check valve.

Defective air tank.

Leaking o-ring.

It is normal for “some” pressure drop to
occur.

Possible defect in safety valve.

Defective check valve.

Prolonged excessive use of air.

Compressor is not large enough for air
requirement.

Restricted air intake filter.

Hole in hose.

Check valve restricted.

Air leaks.

Excessive tank pressure - safety
valve pops off.

Air leaks at fittings.

Air leaks at or inside check valve.

Air leaks at pressure switch
release valve.

Air leaks in air tank or at air tank
welds.

Air leaks between head and valve
plate.

Pressure reading on the regulated
pressure gauge drops when an
accessory is used.

Air leak from safety valve.

Knocking Noise.

Compressor is not supplying
enough air to operate accesso-
ries.

DO NOT DRILL INTO, WELD OR OTHERWISE
MODIFY AIR TANK OR IT WILL WEAKEN. THE
TANK CAN RUPTURE OR EXPLODE. TANK
MUST BE REPLACED.

TROUBLESHOOTING  GUIDE

Содержание MG7-OFTWIN

Страница 1: ...E 12 13 TABLE OF CONTENTS SAFETY GUIDELINES DEFINITIONS Information for preventing damage to equipment This manual contains information that is important for you to know and understand This informatio...

Страница 2: ...er installation and start up cost ANY INCIDENTAL INDIRECT OR CONSEQUENTIAL LOSS DAMAGE OR EXPENSE THAT MAY RESULT FROM ANY DEFECT FAILURE OR MALFUNCTION OF THE PRODUCT Some states do not allow the exc...

Страница 3: ...ER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTITU TIONS TO ALTER THE F...

Страница 4: ...RMED BY AUTHORIZED SERVICE CEN TER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELECTR...

Страница 5: ...ociety of Mechanical Engineers made tested inspectedandregisteredtomeetthestandardsofASME California Code Unit may comply with California Code 462 L 2 M 2 Specification modellabelisonthesideofthetanko...

Страница 6: ...rom a higher to a lower setting first reduce to some pressure less than that desired then bring up to the desired pressure Depending on the air requirements of eachparticularaccessory theoutletregulat...

Страница 7: ...an extension cord must be used do not use with any permanently mounted air compressor use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the p...

Страница 8: ...hecompressorisproperlygrounded have the installation checked by a qualified electrician GROUNDING INSTRUCTION Portable Units RISK OF ELECTRICAL SHOCK In the event of a shortcircuit groundingreducesthe...

Страница 9: ...to OFF and the air regulator or globe valve is closed 2 Attach hose and accessories TOO MUCH AIR PRESSURE CAUSES A HAZARD OUSRISKOFBURSTING CHECKTHEMANUFAC TURER SMAXIMUMPRESSURERATINGFORAIR TOOLS AND...

Страница 10: ...w the check valve turn counterclockwise using a socketwrench 6 Check that the valve disc moves freely inside the check valveandthatthespringholdsthediscintheupper closed position The check valve may b...

Страница 11: ...oosely around the compressor handle 3 Store the air compressor in a clean and dry location Before you store the air compressor make sure you do the following 1 Review the Maintenance and Operating Pro...

Страница 12: ...you need a larger compressor Clean or replace air intake filter Do not operate the air compressor with the filter removed See page 8 Check and replace if required Remove and clean or replace Tighten...

Страница 13: ...and terminal box area Contact an Authorized Warranty Service Center for inspection or replacement if necessary Have checked by an Authorized Warranty Service Center Do not operate the compressor in th...

Страница 14: ...14 ENG SERVICE NOTES NOTAS DE SERVICIO NOTES SUR LE SERVICE...

Страница 15: ...15 ENG SERVICE NOTES NOTAS DE SERVICIO NOTES SUR LE SERVICE...

Страница 16: ...DeVilbiss Air Power Company 213 Industrial Drive Jackson TN 38301 9615 GENERAL MANUAL FOR PERMANENTLY LUBRICATED TWIN CYLINDER AIR COMPRESSORS SERVICE NOTES...

Отзывы: