Operate the air compressor in a clean, dry and well ventilated area.
The air intake filter must be kept clear of obstructions which could
reduce air delivery of the air compressor. The air compressor should
be located at least 12" away from walls or other obstructions that
could interfere with the flow of air through the fan bladed flywheel.
The air compressor crankcase and head are designed with fins to
provide proper cooling.

The flywheel side of the outfit should be placed toward the wall and
protected with a totally enclosed belt guard. In no case should the
flywheel be closer than 12 to 18 inches from the wall or other
obstruction that will interfere with the flow of air through the fan
bladed flywheel. The area should allow space on all sides for air
circulation and for ease of normal maintenance. Keep the outfit away
from areas which have dirt, vapor, and volatile fumes in the atmo-
sphere which may clog and gum the intake filter and valves, causing
inefficient operation.

If humidity is high, an air filter can be installed in line to remove
excessive moisture. Closely follow instructions packaged with the
filter for proper installation. It must be installed as close as possible
to the accessory.

The air compressor should be as near to air outlets as possible in
order to avoid long pipe lines. Do not place the air compressor where
heat is excessive.

Do not use an extension cord. To avoid voltage drop and power loss
to the motor, use extra air hose instead of an extension cord.

Anchoring of Vertical Unit

INSTALLATION AND BREAK-IN PROCEDURES

THE MANIFOLD ASSEMBLY DOES NOT PROVIDE
ADEQUATE STABILITY OR SUPPORT FOR LIFTING
THE UNIT. IF THE OUTFIT MUST BE MOVED, USE
THE TANK FOR LIFTING.

VIBRATION CAN WEAKEN THE AIR TANK AND CAUSE
AN EXPLOSION. THE COMPRESSOR MUST BE PROP-
ERLY MOUNTED AS ILLUSTRATED BELOW.

Air Compressor Anchoring Methods

Location of the Air Compressor

DESCRIPTION OF OPERATION

Drain Valve:

 The drain valve is located at the base of the air  tank and

is used to drain condensation at the end of each use.

Motor Thermal Overload Protector:

  The electric motor has an

automatic thermal overload protector. If the motor overheats for any
reason, the thermal overload protector will shut off the motor. The
motor must be allowed to cool before restarting.

ON/AUTO - OFF Switch:

  Turn this switch ON to provide automatic

power to the pressure switch and OFF to remove power at the end
of each use.

Air Intake Filter:

  This filter is designed to clean air coming

 

into the

pump. This filter must always be clean and ventilation openings free
from obstructions. See "Maintenance".

Air Compressor Pump: 

 To compress air, the pistons moves up and

down in the cylinder.  On the downstroke, air is drawn in through the
air intake valves.  The exhaust valve remains closed.  On the upstroke
of the piston, air is compressed.  The intake valves close and
compressed air is forced out through the exhaust valve, through the
outlet tube, through the check valve and into the air tank.  Working
air is not available until the compressor has raised the air tank
pressure above that required at the air outlet.

Check Valve: 

 When the air compressor is operating, the check valve

is “open”, allowing compressed air to enter the air tank.  When the
air compressor reaches “cut-out” pressure, the check valve “closes”,
allowing air pressure to remain inside the air tank.

Pressure Release Valve: 

 The pressure release valve located on the

side of the pressure switch, is designed to automatically release
compressed air from the compressor head and the outlet tube when
the air compressor reaches “cut-out” pressure or is shut off.  If the
air is not released, the motor will try to start, but will be unable to.  The
pressure release valve allows the motor to restart freely.  When the
motor stops running, air will be heard escaping from the valve for a
few seconds.  No air should be heard leaking when the motor is
running, or continuous leaking after unit reaches cut-out pressure.

Pressure Switch: 

 The pressure switch automatically starts the

motor when the air tank pressure drops below the factory set “cut-
in” pressure.  It stops the motor when the air tank pressure reaches
the factory set “cut-out” pressure.

Shut-off Valve:

  Turn the knob counterclockwise to open the valve

and clockwise to close.

Safety Valve: 

 If the pressure switch does not shut off the air

compressor at its cut-out pressure setting, the safety valve will
protect against high pressure by “popping out” at its factory set
pressure (slightly higher than the pressure switch cut-out setting).

Tank Pressure Gauge: 

 The tank pressure gauge indicates the

reserve air pressure in the tank. On outfits with no pressure regulator,
this is also the pressure available at the air outlet.

Vertical Units

This compressor should be permanently mounted in place on a level
floor.Vertical air compressors must be bolted to the floor. Bolting
holes are provided in the base feet. Mount the air compressor on a
solid, level foundation. Support compressor weight evenly on all four
feet. Solid shims may be used if necessary.

Содержание MG5-OLSTAT-3A

Страница 1: ...ve the following information Model number of your product Part number and description of the item you wish to purchase Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work TABLE OF CONTENTS SAFETY GUIDELINES 1 WARRANTY STATEMENT 2 WARNING CHART 3 4 SPECIFICATIONS 5 GLOSSARY 5 DUTY CYCLE 5 GENERAL INFORMATION 5 ON RECEIPT INSPECTION 5 DESCRIPTION OF OPERATION 6 INSTALLATION A...

Страница 2: ...t Authorized Warranty Service Center that provides on site service calls for service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company ExCell Manufacturing Merchandise sold as reconditioned floor models and or display models Any damaged or incomplete equipment sold as is Merch...

Страница 3: ...TTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUTIONS TO ALTER THE FACTORY SET OPERATING PRESSURES FOR ESSENTIAL CONTROL OF AIR PRES SURE YOU MUST INSTALL A PRESSURE REGULATOR AND PRESSURE GAUGE TO THE AIR OUTLET OF YOUR COMPRESSOR FOLLOW THE EQUIPMENT MANUFACTUR ERS RECOMMENDATION AND NEVER EXCEED THE MAXIMUM ALLOWABLE PRES SURE R...

Страница 4: ...OMPONENTS REMOVED OR DAMAGE ANY ELECTRICAL WIRING OR REPAIRS RE QUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CEN TER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELECTRICAL GROUNDING CORRECT VOLTAGE AND AD EQUATE FUSE PROTECTION ALWAYS WEAR ANSI Z87 1 APPROVED SAFET...

Страница 5: ... 50 of one hour is DUTY CYCLE considered misuse because the air compressor is undersized for the required air demand Maximum compressor pumping time per hour is 30 minutes You have purchased an air compressor unit consisting of an aluminum 2 cylinder single stage air compressor pump with cast iron sleeves an air tank and associated controls and instru ments You will also find a Parts Manual Your a...

Страница 6: ... end of each use Air Intake Filter This filter is designed to clean air coming into the pump This filter must always be clean and ventilation openings free from obstructions See Maintenance AirCompressorPump Tocompressair thepistonsmovesupand down in the cylinder On the downstroke air is drawn in through the airintakevalves Theexhaustvalveremainsclosed Ontheupstroke of the piston air is compressed...

Страница 7: ...ious damage may result if the following break in instructions are not closely followed Break in Procedures Wiring Instructions Perform electrical wiring according to the following instructions Install the compressor outfit as close to the main power supply as possible This practice will avoid using long lengths of electrical wiringforthepowersupplywhichcancausepowerlossanddamage to the motor When ...

Страница 8: ...g It is recommended that a flexible coupling be installed between the air discharge valve outlet and main air distribution line to allow for vibration To remove dirt oil and water install a separator in the main distribution line Install separator 5 to 6 feet from compressor to allowtheairtocooltoroomtemperaturebeforepassingthroughthe separator Additional separators or filters may be used dependin...

Страница 9: ...r air leaks Even minor leaks can cause the compressor to over work resulting in premature breakdown or unsatisfactory performance 4 Check for any unusual vibration and noise 5 Check for oil leaks Correct any leaks found Compressed air from the outfit may contain water condensation and oil mist Do not spray unfiltered air at an item that could be damaged by moisture or oil mist Some air operated to...

Страница 10: ...as been drained close the drain cock The air compressor can now be stored NOTE If the drain cock valve is plugged release all air pressure The valve can then be removed cleaned and reinstalled DRAIN TANK DAILY WATER WILL CONDENSE IN THE AIR TANK IF NOT DRAINED WATER WILL CORRODE AND WEAKEN AIR TANK CAUSING A RISK OF AIR TANK RUPTURE OPERATING PROCEDURES cont d 5 When You Are Finished drain tank pr...

Страница 11: ...h 7 8 4 Check that the valve disc moves freely and that the spring holds the disc in the upper closed position The check valve may be cleaned with a solvent 5 Apply sealant to the check valve threads Reinstall the check valve turn clockwise DO NOT OVERTIGHTEN 6 Replace the outlet tube and tighten top and bottom tube nuts DO NOT OVERTIGHTEN Safety Valve Inspection and Replacement IF THE SAFETY VALV...

Страница 12: ...URE CONTROL RELATED DEVICE IF REPLACEMENT IS NECESSARY THE SAME RATED SWITCH MUST BE USED CONTACT A DEVILBISS AIR POWER AUTHORIZED SERVICE CENTER FOR REPLACEMENT Motor Overload Protector Reset The motor has a manual thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting Turn the unit o...

Страница 13: ...ervice Center to check remove or re place switch Tighten fittings where air can be heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN A defective check valve results in a con stant air leak at the pressure release valve when there is pressure in the tank and the compressor is shut off Remove and clean or replace check valve DO NOT OVER TIGHTEN See page 11 Remove and replac...

Страница 14: ...R TIGHTEN See page 11 Check wiring connection inside pressure switch and motor terminal box area 1 Check fuse box for blown fuse and re place if necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit 2 Check for proper fuse only Buss Fusetron Type T fuses are accept able 3 Check for low voltage conditions 4 Rem...

Страница 15: ...y and flywheel must be in line within 1 32 See Pulley and Flywheel Alignment section on page 12 Adjust belt tension See Belt Replace ment section on page 12 Add oil to top of fill hole in base If there is an excessive amount of pressure drop when the accessory is used adjust the regulator NOTE Adjust the regulated pressure under flow conditions while the accessory is being used See oil recommendat...

Страница 16: ...DeVilbiss Air Power Company 213 Industrial Drive Jackson TN 38301 9615 General Manual Oil Lubricated Single Stage Stationary Air Compressors SERVICE RECORD ...

Отзывы: