background image

5 — ENG

HAZARD

RISK OF

ELECTRICAL SHOCK

RISK FROM

FLYING OBJECTS

RISK TO BREATHING

RISK FROM

MOVING PARTS

RISK OF BURNS

WHAT CAN HAPPEN

REPAIRS ATTEMPTED BY UNQUALIFIED
PERSONNEL CAN RESULT IN SERIOUS
INJURY OR DEATH BY ELECTROCUTION.

ELECTRICAL GROUNDING:  

FAILURE TO

PROVIDE ADEQUATE GROUNDING TO THIS
PRODUCT COULD RESULT IN SERIOUS
INJURY OR DEATH FROM ELECTROCU-
TION.

  SEE GROUNDING INSTRUCTIONS.

THE 

COMPRESSED AIR

 STREAM 

CAN

CAUSE SOFT TISSUE DAMAGE

 TO EX-

POSED SKIN 

AND CAN PROPEL

 DIRT,

CHIPS, 

LOOSE PARTICLES

 AND SMALL

OBJECTS AT 

HIGH SPEED

, RESULTING IN

PROPERTY DAMAGE OR PERSONAL INJURY.

THE 

COMPRESSED AIR

 FROM YOUR

COMPRESSOR 

IS NOT SAFE FOR BREATH-

ING!

  THE AIR STREAM MAY CONTAIN

CARBON MONOXIDE, TOXIC VAPORS OR
SOLID PARTICLES.

SPRAYED MATERIALS

 SUCH AS PAINT,

PAINT SOLVENTS, PAINT REMOVER,
INSECTICIDES, WEED KILLERS, ETC..

CONTAIN HARMFUL VAPORS

 AND POI-

SONS.

MOVING PARTS CAN CAUSE SERIOUS
INJURY

 OR DAMAGE IF THEY COME INTO

CONTACT WITH YOU OR YOUR CLOTHING.

ATTEMPTING TO OPERATE OR REPAIR
COMPRESSOR WITH PROTECTIVE
SHROUDS REMOVED CAN EXPOSE YOU
TO MOVING PARTS AND ELECTRICAL
SHOCK.

A PORTABLE 

COMPRESSOR CAN FALL

FROM A TABLE, WORKBENCH OR ROOF

CAUSING DAMAGE TO THE COMPRESSOR
WHICH COULD EXPOSE YOU TO HAZARD-
OUS MOVING OR ELECTRICAL PARTS.

THE 

COMPRESSOR CYCLES AUTOMATI-

CALLY WHEN

 THE 

PRESSURE SWITCH IS

IN THE ON/AUTO POSITION.

TOUCHING EXPOSED 

METAL SUCH AS THE

COMPRESSOR HEAD OR OUTLET TUBE

CAN RESULT IN SERIOUS BURNS.

HOW TO PREVENT IT

ANY 

ELECTRICAL WIRING OR REPAIRS

REQUIRE ON THIS PRODUCT 

SHOULD BE

PERFORMED BY AUTHORIZED SERVICE
CENTER PERSONNEL 

IN ACCORDANCE

WITH NATIONAL AND LOCAL ELECTRICAL
CODES.

MAKE CERTAIN THAT

 THE 

ELECTRICAL

CIRCUIT

 TO WHICH THE COMPRESSOR IS

CONNECTED 

PROVIDES PROPER ELEC-

TRICAL GROUNDING, CORRECT VOLTAGE
AND ADEQUATE FUSE PROTECTION.

ALWAYS WEAR ANSI Z87.1 APPROVED
SAFETY GLASSES WITH SIDE SHIELDS

WHEN USING THE COMPRESSOR.

NEVER POINT ANY NOZZLE OR SPRAYER
TOWARD ANY PART OF THE BODY OR AT
OTHER PEOPLE OR ANIMALS.

NEVER INHALE AIR FROM THE COMPRES-
SOR

 EITHER DIRECTLY OR FROM A

BREATHING DEVICE CONNECTED TO THE
COMPRESSOR.

WORK IN AN AREA WITH GOOD CROSS-
VENTILATION.

 READ AND 

FOLLOW THE

SAFETY INSTRUCTIONS

 PROVIDED ON THE

LABEL OR SAFETY DATA SHEETS 

FOR THE

MATERIAL YOU ARE SPRAYING.  

   

USE A

NIOSH/MSHA APPROVED RESPIRATOR

DESIGNED FOR USE WITH YOUR SPECIFIC
APPLICATION.

DO NOT REMOVE THE PROTECTIVE
COVERS

 FROM THIS PRODUCT.  

NEVER

OPERATE

 THE 

COMPRESSOR WITH

GUARDS

 OR COVERS WHICH ARE DAM-

AGED OR 

REMOVED.

ANY 

REPAIRS

 REQUIRED ON THIS 

PROD-

UCT SHOULD BE PERFORMED BY AUTHO-
RIZED SERVICE CENTER PERSONNEL.

ALWAYS 

OPERATE COMPRESSOR IN A

STABLE SECURE POSITION

 TO PREVENT

ACCIDENTAL MOVEMENT OF THE UNIT.

NEVER OPERATE COMPRESSOR ON A
ROOF OR OTHER ELEVATED POSITION.
USE ADDITIONAL AIR HOSE TO REACH
HIGH LOCATIONS.

ALWAYS 

TURN OFF

 THE 

COMPRESSOR,

BLEED PRESSURE FROM THE AIR HOSE
AND TANK UNPLUG FROM ELECTRICAL
OUTLET BEFORE PERFORMING MAINTE-
NANCE OR ATTACHING TOOLS AND AC-
CESSORIES.

NEVER TOUCH ANY EXPOSED METAL
PARTS ON COMPRESSOR

 DURING OR

IMMEDIATELY AFTER OPERATION.  

COM-

PRESSOR WILL REMAIN HOT

 FOR SEV-

ERAL MINUTES AFTER OPERATION.

CTMCWPS — 5/1/97

Содержание FAC28-1

Страница 1: ...a circuit protected by fuses use quick acting fuses MGP FAC28 1 4 6 98 DeVILBISS AIR POWER COMPANY DeVilbiss Air Power Company 213 Industrial Dr Jackson TN 38301 9615 SAFETY GUIDELINES DEFINITIONS IM...

Страница 2: ...of Air Compressor 7 INSTALLATION AND BREAK IN PROCEDURES 7 8 Location of Air Compressor 7 Page Extension Cords 7 Voltage and Circuit Protection 7 Grounding Instructions 8 Additional Regulators and Co...

Страница 3: ...service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Merchandise sold a...

Страница 4: ...MPRESSOR OUTFIT NEVER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUT...

Страница 5: ...Y ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICA...

Страница 6: ...restart automatically The low pressure at which the motor automatically re starts is called cut in pressure 1 Set the ON OFF switch to OFF and unplug the cord 2 Reviewthe OperatingProcedures section p...

Страница 7: ...d a 3 slot receptacle that will accept the plug on the compressor ingoodcondition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gaugenumberdecreases 12AWG 10AWGand 8 AWG may als...

Страница 8: ...t if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet t...

Страница 9: ...OFF AUTO lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting...

Страница 10: ...e heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN THE TANK...

Страница 11: ...arts Have checked at an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning Possible defective motor Have checked at an Authorized Warr...

Страница 12: ...SSP 490 CAC 1254 KEY NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DESCRIPTION Safety Valve Drain Valve Wheel 6 2 used Shoulder Bolt 2 used Nut Hex 3 8 16 UNC 2B 2 used Handle Screw 10 16 x 1...

Страница 13: ...13 ENG PUMP DIAGRAM...

Страница 14: ...ket Valve plate assembly O ring OutletTube Rod assembly Screw 3 8 16 x 1 25 LG hex socket flat head Cylinder sleeve Motor Endbellassembly Timingbelt Pumpisolator Shroud right Shroud left Screw 10 9 x...

Страница 15: ...15 ENG SERVICE NOTES...

Страница 16: ...location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following inf...

Отзывы: