background image

12 — ENG

AIR COMPRESSOR DIAGRAM & PARTS LIST

PART NUMBER

97503734
SS-2707
CAC-4299
CAC-60
SSF-8080-ZN
AC-0345
SSF-612
AC-0364
AC-0353
SUDL-413-2
AC-0027-2
SSP-480
AC-0007
AC-0009-1
AC-0010-1
H-2101
SSP-473
CAC-1275
SSP-490
CAC-1254

KEY

NO.

1

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

DESCRIPTION

Safety Valve
Drain Valve
Wheel 6" (2 used)
Shoulder Bolt (2 used)
Nut Hex 3/8-16 UNC-2B (2 used)
Handle
Screw #10 - 16 x 1 Type AB (2 used)
Molded Foot Bumper (2 used)
Pressure Switch
Cord Assembly
Manifold
Nipple 1/4 - 18 NPT x 2.50
Regulator
Gauge - Right Hand
Gauge - Left Hand
Adaptor
Nut Sleeve
Check Valve
Face Bushing
Isolator (4 used)

Содержание FAC28-1

Страница 1: ...a circuit protected by fuses use quick acting fuses MGP FAC28 1 4 6 98 DeVILBISS AIR POWER COMPANY DeVilbiss Air Power Company 213 Industrial Dr Jackson TN 38301 9615 SAFETY GUIDELINES DEFINITIONS IM...

Страница 2: ...of Air Compressor 7 INSTALLATION AND BREAK IN PROCEDURES 7 8 Location of Air Compressor 7 Page Extension Cords 7 Voltage and Circuit Protection 7 Grounding Instructions 8 Additional Regulators and Co...

Страница 3: ...service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Merchandise sold a...

Страница 4: ...MPRESSOR OUTFIT NEVER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUT...

Страница 5: ...Y ELECTRICAL WIRING OR REPAIRS REQUIRE ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICA...

Страница 6: ...restart automatically The low pressure at which the motor automatically re starts is called cut in pressure 1 Set the ON OFF switch to OFF and unplug the cord 2 Reviewthe OperatingProcedures section p...

Страница 7: ...d a 3 slot receptacle that will accept the plug on the compressor ingoodcondition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gaugenumberdecreases 12AWG 10AWGand 8 AWG may als...

Страница 8: ...t if the followingbreak ininstructionsare notcloselyfollowed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet t...

Страница 9: ...OFF AUTO lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting...

Страница 10: ...e heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD OR OTHERWISE MODIFY AIR TANK OR IT WILL WEAKEN THE TANK...

Страница 11: ...arts Have checked at an Authorized Warranty Service Center Do not operate the compressor in the paint spray area See flammable vapor warning Possible defective motor Have checked at an Authorized Warr...

Страница 12: ...SSP 490 CAC 1254 KEY NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DESCRIPTION Safety Valve Drain Valve Wheel 6 2 used Shoulder Bolt 2 used Nut Hex 3 8 16 UNC 2B 2 used Handle Screw 10 16 x 1...

Страница 13: ...13 ENG PUMP DIAGRAM...

Страница 14: ...ket Valve plate assembly O ring OutletTube Rod assembly Screw 3 8 16 x 1 25 LG hex socket flat head Cylinder sleeve Motor Endbellassembly Timingbelt Pumpisolator Shroud right Shroud left Screw 10 9 x...

Страница 15: ...15 ENG SERVICE NOTES...

Страница 16: ...location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following inf...

Отзывы: