background image

© 2003 ITW Finishing Systems and Products

 

Installation

 

Important: 

To ensure that this 

equipment reaches you in first class 
condition, protective coatings have 
been used. 

Flush the equipment 

through with a suitable solvent 
before use. 

1.  Attach air hose to connector (13). 

Recommended hose size 8 mm 

bore. The hose must be conductive 
and electrical bond from the 
spraygun to earth should be 
checked with an ohmeter. A 
resistance of less than 10

6

 Ohms is 

recommended. 

2  Attach fluid supply hose to Fluid 
 

Inlet (15).  

 

1.  Turn off air and coating supply and 

relieve  pressure in the supply lines, 
or if using QD system, disconnect 
from airline and fluid line. 

2.  Remove air cap (1) and clean. If 

any of the holes in the cap are 
blocked with coating material use a 
toothpick to clean. Never use metal 
wire which could damage the cap 

and produce distorted spray 
patterns 

3.  Ensure the tip of the nozzle (2) is 

clean and free from damage. Build 
up of dried paint can distort the 
spray pattern. 

4.  Lubrication – stud/screw (6), needle 

(9) and air valve (11) should be 
oiled each day. 

Preventative Maintenance

 

Operation

 

1. M i x   c o a t i n g   m a t e r i a l   t o 

manufacturers instructions 

2. Turn needle adjusting screw (7) 

clockwise to prevent movement.  

3. Turn spreader valve (5) counter-

clockwise to fully open. 

4. Adjust inlet air pressure (For 

r e c o m m e n d e d   f i g u r e s   s e e 
Specifications) at the gun inlet with 
the gun triggered. 

(pressure gauge 

a t t a c h m e n t   s h o w n   u n d e r 
Accessories is recommended for 
this).

 

5.  Turn needle adjusting screw counter 

clockwise until first thread shows. 

6.  Test spray. If the finish is too dry 

reduce airflow by reducing air inlet 
pressure or by the Airflow Valve (14). 
Screw the Adjusting Knob (14) in to 
reduce pressure.  

7.  If finish is too wet reduce fluid flow 

by turning needle screw (7) 
clockwise or reducing the fluid 
pressure. If atomisation is too 
coarse, increase inlet air pressure. If 
too fine reduce inlet pressure. 

8.  The pattern size can be reduced by 

turning adjusting valve (5) clockwise. 

9.  Hold gun perpendicular to surface 

being sprayed. Arcing or tilting may 
result in uneven coating. 

10. The recommended spray distance is 

150-200 mm (6”-8”). 

11. 

Spray edges first. Overlap each 
stroke a minimum of 50%. Move gun 
at a constant speed. 

12. Always turn off air and fluid supply 

and relieve pressure when gun is not 
in use. 

 

E

E

 

 

Содержание Compact COM-P522B-14

Страница 1: ...E E P 1 12 SB E 2 530 Operation Manual HVLP and Trans Tech Pressure Feed Spraygun ISS 04...

Страница 2: ...Distributor or ITW Finishing direct E E Model Part Number Example COM P522B 14 Aircap Fluid nozzle size 14 1 4 mm Gunbody Finish B Blue Anodised ITW Finishing Systems and Products reserve the right t...

Страница 3: ...praying and follow any recommendations If In Doubt Contact Your Material Supplier The use of respiratory protective equipment is recommended at all times The type of equipment must be compatible with...

Страница 4: ...622 K5 1 9 Needle SP 300S K 1 085 10 11 12 13 14 16 18 20 22 e g 14 1 4 mm Needle Plastic tipped SP 300P K 10 12 14 e g 14 1 4mm 10 Airvalve housing seal SP 612 K 1 11 Spindle 1 12 Trigger SP 617 K 1...

Страница 5: ...psi Maximum static Fluid inlet pressure P2 15 bar 218 psi Nominal gun Air inlet pressure with gun triggered 2 5 bar 36 psi 523 Trans Tech Air Cap 2 bar 29 psi 522 510 Trans Tech Air Cap 1 4 bar 20 psi...

Страница 6: ...tenance Operation 1 M i x c o a t i n g m a t e r i a l t o manufacturers instructions 2 Turn needle adjusting screw 7 clockwise to prevent movement 3 Turn spreader valve 5 counter clockwise to fully...

Страница 7: ...Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front Seal to Service Tool 10 Fit new Seal to gunbody and press firmly to ensure Seal is engaged 11 Fit New Valve Seat...

Страница 8: ...2003 ITW Finishing Systems and Products 8 1 2 3 4 5 6 7 8...

Страница 9: ...2003 ITW Finishing Systems and Products 9 9 10 11 11a 12 13 14 15...

Страница 10: ...2003 ITW Finishing Systems and Products 10 17 18 19 20 21 16...

Страница 11: ...5 1 K3 Regulator Gauge Attachment order HAV 501 B Pressure gauge Attachment order GA 515 Gun Mounted Regulator order DVR 501 Spraygun Lubricant order GL 1 K10 Roundspray Aircap COM 500R HVLP Mode Air...

Страница 12: ...ebig Stra e 31 63128 Dietzenbach Tel 060 74 403 1 Telefax 060 74 403300 Website address http www itw finishing de ITW Surfaces Et Finitions 163 171 avenue des Aur ats B P 1453 26014 VALENCE CEDEX FRAN...

Отзывы: