Quick View Menu Layout
The Quick View Menu shows a summary of information which is reported in the SmartCode data. Information in the Quick
View includes: Number of days used more than 4 hours (or can be set to 5 hours by clinician), AHI (Apnea/Hypopnea
Index), High Leak percent (percent of time at leak >95 L/m), and Daily Usage (average hours per day used). Each
parameter can be viewed in any of four time periods, 1 day, 7 days, 30 days and 90 days.
The following chart shows the Quick View information that is available on your CPAP display if viewing this information has
been enabled by your provider. The Quick View menu shows a summary of your SmartCode data for 1, 7, 30, and 90 day
periods. Each of the time periods contains info for “Number of Days > x hrs”, Apnea Hypopnea Index (AHI), High Leak %
(>95 L/m) and Average Daily Hours of while breathing use.
Diagram of CPAP displays
Days ≥ 4H
1d
1/ 1 (100%)
AHI 1d
31.5+
High Leak
1d
31+%
Daily Usage
1d
9.3+ hours
Exit Menu
Press
Days ≥ 4H
7d
7/ 7 (100%)
AHI 7d
31.5+
High Leak
7d
31+%
Daily Usage
7d
9.3+ hours
Days ≥ 4H
30d
30/30 (100%)
AHI 30d
31.5+
High Leak
30d
31+%
Daily Usage
30d
9.3+ hours
Days ≥ 4H
90d
90/90 (100%)
AHI
90d
31.5+
High Leak
90d
31+%
Daily Usage
90d
9.3+ hours
UP (
) DOWN (
) buttons
RIGHT
(
) LEFT
(
) buttons
Definitions
Not all of the features in the table below are available in all models; some are optional and some depend on what your
physician and/or home care provider has selected. The table shows the items you may see, and describes the feature
associated with each item. Also, some features are only available in certain modes or with the DeVilbiss SmartLink
Therapy Management Module – these are noted in the ‘Mode’ column below. If you do not see some of these options, your
model or confi guration does not support them.
Please note that the values displayed are examples only.
Display Example
Description
Mode
OFF
Blower OFF, the CPAP unit is plugged in to AC or DC power with the
blower OFF.
All
Quick View Menu
Press
Pressing the down key enters the Quick View menu. NOTE: The
“Quick View” menu is only shown if enabled from the clinical menu.
All
P: 5.0
Auto
Heat:Off
This is the default screen when the device is turned on. The actual
mask pressure and heater setting are shown. The displayed pressure
may vary slightly while breathing. If the heater system is not
connected, the heat setting will be blank.
All
Set Pressure
10.0
cmH2O
This is a prescription setting which controls the operating pressure.
CPAP Mode
Delay Time
45 minutes
Selectable delay time setting. Your provider has set the delay time.
All
Delay Pressure
5.0 cmH2O
This is a prescription setting which controls the operating pressure
during the delay time.
CPAP Mode