Introduction to Filtering
Orbitor 6000 Installation & Applications Guide —
3.3
Example:
~12-80
This filter pattern will match if the packet
information starting at the 12th octet does not
equal the 80 of the filter pattern.
( )
brackets
Used in pattern filters to separate portions of filter patterns for specific
operators.
Example: 12-80&(14-24|14-32) This filter pattern will be checked in two
operations. First the section in brackets will be
checked and then the results of the first check
will be used in the second check using the first
portion of the filter patter. If the packet
information starting at the 14
th
octet equals 24 or
32, and the information at the 12
th
octet equals
80, the filter pattern will match.
Popular Filters
Shown here are some of the more commonly used pattern filters.
Bridge
Bridge pattern filters are applied to Ethernet frames that are bridged only. When the
Orbitor is operating as a router, all routed frames will be unaffected by the bridge pattern
filters.
IP & Related Traffic
IP & Related Traffic
Forward only
~(12-0800|12-0806)
Filter
(12-0800|12-0806)
Novell IPX Frames
Novell IPX Frames
EthernetII
(12-8137)
802.3 RAW
(14-FFFF)
802.2
(14-E0E0)
802.2 LLC
(14-AAAA&20-8137)
NetBIOS &NetBEUI (Windows For Workgroups)
NetBIOS & NetBEUI (Windows For Workgroups)
Filter
(14-F0F0)
Forward only
~(14-F0F0)