Analogue/Digital flexible I/O's
The tcp184 has eight flexible Input ports, numbered 1-8, which can be your selection of:
1. Digital input with pull-up resistor (allows direct connection of Volt Free Contact, VFC).
2. Digital input without no pull-up resistor, suitable for driving with a 0-5v signal.
3. Analogue input using a 4.096v reference. 12-bit.
4. Analogue input using a 5v reference. 12-bit.
5. High speed counter, up to 2000 counts/second
Representative input circuit.
The transistor is used to turn on/off the 10k pull-up resistor.
Another 10k resistor and 10n capacitor provides an input filter.