tcp184
tcp184
User Manual v4.10
Counter/Timers
Count input pulses or time events.
There are a total of eight counter/timers available, selected with Counter No. box. Each
counter can count digital inputs at a maximum speed of 20Hz (20 counts per second) or high
speed counter inputs at a maximum speed of 2KHz (2000 counts per second).
Counter Name
Each counter/timer may be named and this name appears on the application page and email
notifications.
Count Input
Each counter/timer is capable of being a timer by entering T1 into its count input box. T1 is an
internal 1Hz timer that will advance the count once per second. If and input is specified then
any pulses on that input will be counted. D4 will count pulses on input 4 at up to 20Hz. HSC4
will count at up to 2KHz. Make sure the input is correctly configured in the Input/output tab.
Note that “HSC4” directs the system to use the high speed counter. HSC4 cannot be part of a
boolean equation.
Capture Input
This is the event that will cause the current counter value to be stored in the capture register.
The capture register is displayed on the application page, and may also be read using the
TCP/IP commands.