A. Excessive Noise
B. Oil Pumping and
Excessive Carbon
Formation
or
Appearance of Water
and Oil in the in the Air
Lines.
1. Install a moisture separator and/or oil
filter in the air line at least 8 feet
from the air receiver.
2. Check for air leaks. If no leaks are
found, you may require an additional
compressor unit, as your air demand
is too much for the existing unit.
3. Clean or replace the piping. Contact
Devair or contact your local
Distributor or Service Centre for sizing
requirements.
4.
Replace air intake filter.
5.
Fill to proper level.
6.
Check 'Lubrication' in this manual or
contact your local Devair Distributor or
Service Centre.
7.
Clean or replace as required.
8.
Replace valve assemblies.
9.
Replace rings and check cylinder
walls for scoring.
1.
High ambient temperature and/or
humidity.
2. High percentage of running time. (80%
to 100%)
3. Obstructed or undersized air intake
piping, where remote air Intake is
used.
4.
Restricted air intake filter.
5.
Overfilling the crankcase with oil.
6.
Wrong type of oil.
7.
Carbonned exhaust valves.
8.
Worn valves.
9.
Worn piston rings.
1. Loose flywheel or motor pulley.
2. Loose valve.
3.
If noisy only during start-up, check for
loose belts.
4. Vibrating beltguard, piping, or loose belts.
5. Unit not installed level.
6.
Improper grade or level of oil in crankcase.
7. Carbon or other foreign material on head
of piston.
8. Normal sound amplified through floor or
carried through remote air intake (when
used).
9. If the noise is a knock, and cannot be
attributed to any of the above, the
problem could be worn bearings.
1.
Tighten as required.
2. Inspect valve for damage. Replace as
required. Check to ensure valve is
seated properly in head. Reinstall,
tightening valve plug and set screw
3. Tighten until no slippage is apparent.
Allow some slack.
4. Tighten as required.
5. Ensure that unit is mounted level.
6. Use correct oil and ensure level is
correct.
7. Clean top of piston. Check cylinder
walls for scoring, etc.
8. Mount unit on vibration isolators.
Insulate intake piping from building.
9. Worn main bearings can usually be
detected by noticeable end play on the
flywheel. Replace the main bearings.
Worn connecting rod insert bearings
or connecting rods may be detected by
removing a valve and watching the
piston while moving the flywheel by
hand. If the flywheel can be moved at
midstroke without movement of the
piston, bearing inserts or connecting
rod may need to be replaced.
Suggested Correction
Condition
Cause
When servicing the Compressor, shut off all power to the Unit, and
drain the Tank of air pressure. Always replace the BeltGuard after
adjusting the Belts or Pulleys.
Trouble-Shooting Guide
- 20 -
HDI-01
Mar ‘07
Distributed by: CENTRAIR Air Systems & Supplies, 68 Hooper Rd., Unit 5, Barrie, ON L4N 8Z9
Phone: 705-722-5747 Fax: 705-722-5458 [email protected] www.centrair.ca