It is your responsibility to ensure that the
Compressor Unit is electrically connected in a
safe and correct manner. Any electrical work
must be carried out by a competent Electrician,
and be done is such a way that it meets all
applicable Codes and Regulations.
A Magnetic Starter, as shown below, must be an
integral part of the Compressor Unit circuit as it
provides overload protection to the Electric
Motor. A Magnetic Starter can be purchased
separate from the Unit, or factory-mounted at
time of manufacture.
Typical Electrical Installation
of a Compressor Unit
Typical Magnetic Starter Wiring
(Subject to Local Codes & Authorities)
Please note that, under normal
conditions, the Compressor Unit will
operate intermittently .
The Unit starts/stops without warning.
Should it be necessary to service the
Unit, ensure the power source has been
shut down and locked off. This must be
done to prevent personal injury, or
damage to the unit.
Do not attempt to operate the Air
Compressor Unit without first checking
the Oil level in the Pump. Add Oil as
required. Serious damage may result
from use without Oil.
Failure to connect the Compressor
correctly to your building's electrical
services may result in serious
personal injury, or damage to
equipment.
Pressure
Switch
Motor
C
L
L L
3
2
1
Installation - Electrical
Main Fuse Box
Magnetic Starter
Fused Disconnect
or Circuit Breaker
- 11 -
HDI-01
Mar ‘07