Encoder Housekeeping Commands
REGISTER INTERROGATION
Typing: RDS?
8
returns the status of all flag and ID settings and the contents of static message
buffers to the screen. This was illustrated in section
ENCODER INITIALIZATION
The “initialize” command is invoked by typing: INIT
8
. This is used to reestablish encoder
operation in the unlikely event of an internal software ‘crash,’ or for any other reason to restore the
factory defaults
(see “Factory Defaults” on page 86)
. INIT
8
is an emergency recovery command
only. It is not necessary to execute INIT
8
prior to updating any encoder programming.
ENCODER RESET
Typing:
RESET
8
initiates a ‘hardware reset’ equivalent to turning the encoder off and back on
again. This reset command does not clear the registers of programming commands that have been
saved as described above.
FIRMWARE VERSION
Type:
REV?
8
for a display of the encoder’s firmware version. This might prove important
in determining whether differences exist between SmartGen 6.0 encoders purchased at different
times.
NETWORK SETTINGS
Type: NET?
8
for a display of the encoder’s Network Settings, which include IP Address,
Subnet Mask, Gateway, DNS Server and DCHP Client. This is useful when information about
Network Settings is needed at a glance; instead of interrogate each one Network Parameter.