Connecting AC Power
FUSEHOLDER
The Fuse holder can be found right under the Mains connector.
Before connecting the AC Power, make sure that the mains supply at your location is in
accordance with SmartGen 6.0’s Power Supply Factory Settings - 100÷240 VAC, 1 Amp Fuse.
CAUTION:
Permanent damage will result if improper AC supply voltage is applied to
SmartGen 6.0 device. Your warranty does not cover damages caused by applying improper supply
voltage, or use of an improper fuse.
POWER CORD
The detachable IEC-type power cord is supplied with the unit. The individual cord conductors
may be color-coded in either of two ways:
1) In accordance with US standards:
BLACK = AC “HOT”
WHITE = AC NEUTRAL
GREEN = EARTH GROUND
2) To European CEE standards:
BROWN = AC “HOT”
BLUE = AC NEUTRAL
GREEN/YELLOW = EARTH GROUND
GROUND LOOPS
Because the unbalanced PILOT OR MPX INPUT and the RDS OR MPX OUTPUT of the
SmartGen 6.0 are chassis-ground-referenced, a mains frequency or RF ground loop could be formed
between the input or output cable shield grounds and the AC power cord ground. A ‘ground-lifting’
AC adapter may well remedy such a situation, although the chassis somehow must be returned
to earth ground for safety. Generally, being screwed-down in the equipment rack will satisfy the
safety requirement.