background image

  

 

Page 3 

 Deva018 Single Axis Sine-Wave Interpolator 

User’s Manual  

 

     Installation and Usage

 

2

 

Installation and Usage 

The Deva018 single axis sine-wave interpolator can accept a variety of input signals, 
including 11µA or 1Vpp differential sine / cosine signals and produce RS422 differential 
square wave quadrature signals.  The interpolation factor may be set to 10, 25, 50 or 100 
times.  For 1Vpp the inputs may be terminated with on board 120ohm resistors.  The 
maximum input rate is 125kHz and the maximum output count rate is 5MHz using x10 
interpolation. 

The Deva018 operates from +5V, which may be supplied either from the input or output 
connector.  

The output connector is pin to pin compatible with all Deva’s encoder 

interface and motion 

control products.  All unused pins are passed through from input to output. 

2.1

 

Connections 

The following table lists the input and output connection for the Deva018. 

Sine Wave Input 

Square-wave output 

15-way HD female 

Signal 

15 -way HD male 

Signal 

Test Connections 

Pin 1 

Ain 

Pin 1 

Aout 

Oscilloscope nA 

Pin 2 

Bin 

Pin 2 

Bout 

Oscilloscope B 

Pin 3 

nTEST 

Pin 3 

nTEST 

0V 

Pin 4 

Min 

Pin 4 

Mout 

 

Pin 5 

** 

Pin 5 

** 

 

Pin 6 

nAin 

Pin 6 

nAout 

Oscilloscope A 

Pin 7 

nBin 

Pin 7 

nBout 

Oscilloscope nB 

Pin 8 

** 

Pin 8 

** 

 

Pin 9 

nMin 

Pin 9 

nMout 

 

Pin 10 

** 

Pin 10 

** 

 

Pin 11 

*(+12V for Deva023)  Pin 11 

*(+12V for Deva023)  +12V as required 

Pin 12 

+5V 

Pin 12 

+5V 

+5V 

Pin 13 

0V 

Pin 13 

0V 

0V 

Pin 14 

Pin 14 

 

Pin 15 

Pin 15 

 

* Connected directly from input to output, no internal connection.  The Pin 11 pass-through may be used to take 
+12V from Deva001, Deva037 or Deva004 via Deva018 to Deva023. 
** Connected directly from input to output, +5V pull up present.  If used, do not exceed 0V to +5V range. 

When connecting single-ended signals it is important to connect the nAin/nBin/nMin signals 
to a suitable reference point.  For example, if the scale outputs a 2Vpp signal on a 2.5V offset 
then the nAin/nBin/nMin inputs should be connected to the 2.5V scale reference voltage. 

Important: If to be used with the Deva023 pre-amp, the Deva018 must be configured for 
voltage mode and A,B termination must be disabled. 

Содержание Deva018

Страница 1: ...L Phone 44 0 151 647 3222 Fax 44 0 151 647 4511 Email sales deva co uk Website www deva co uk CONTENTS Overview Installation and Usage Deva018 Sine Wave Interpolator User s Manual SUPPORT For additional downloadable Support Documentation please visit www deva co uk support downloads Or contact us at support deva co uk SIGNAL CONVERSION GENERATION ...

Страница 2: ...en in good faith by Deva Electronic Controls Ltd Deva Electronic Controls Ltd shall not be liable for any loss or damage howsoever arising that may be attributed to errors within or omissions from this document nor for the use of or application of the information provided herein ...

Страница 3: ...Contents 1 Overview 1 1 1 About this Manual 1 1 2 Deva018 Features 1 1 2 1 Facilities 1 2 Installation and Usage 3 2 1 Connections 3 2 2 Test point connector 4 2 3 Configuration Solder Pads 4 2 3 1 Example settings 5 2 4 018 BRK1 Breakout test board for 018 setup 6 ...

Страница 4: ......

Страница 5: ...nostics metrology and data acquisition This manual describes the installation configuration of Deva018 and the facilities it offers For information regarding its use in conjunction with other Deva products please refer to the relevant User s Manual Programming Guide Note Software support is an ongoing activity if support for a particular application or operating system is not detailed in our docum...

Страница 6: ......

Страница 7: ... 15 way HD female Signal 15 way HD male Signal Test Connections Pin 1 Ain Pin 1 Aout Oscilloscope nA Pin 2 Bin Pin 2 Bout Oscilloscope B Pin 3 nTEST Pin 3 nTEST 0V Pin 4 Min Pin 4 Mout Pin 5 Pin 5 Pin 6 nAin Pin 6 nAout Oscilloscope A Pin 7 nBin Pin 7 nBout Oscilloscope nB Pin 8 Pin 8 Pin 9 nMin Pin 9 nMout Pin 10 Pin 10 Pin 11 12V for Deva023 Pin 11 12V for Deva023 12V as required Pin 12 5V Pin 1...

Страница 8: ... the target controller when test mode is enabled The test connections shown above are recommended 2 3 Configuration Solder Pads There are eight pairs of solder pads that must be shorted to change the configuration of the Deva018 as shown in Figure 2 1 and associated tables Note The default configuration is 11µA x10 interpolation with no termination and is shown shaded grey in the tables IMPORTANT ...

Страница 9: ...1Vpp 2Vpp MIT1 Reserved When differential voltage signals such as 1Vpp are in use it is typical to terminate the signals with 120 ohm resistors Termination is controlled by the following links Termination Link None 120 ohm A term B term M term 2 3 1 Example settings 11µA x10 11µA x50 1Vpp x100 2Vpp x10 Deva 023 A term B term M term CFG0 CFG1 CFG2 CFG3 CFG4 For further information and assistance em...

Страница 10: ...r Deva037 in use Moving switch TEST0 into the closed down position will invoke test mode the next time the 018 1SIN power is cycled When in test mode the signals described above will be present on both the A B test points TP1 and TP2 and header J3 Use the GND test point TP4 for the oscilloscope ground clip The nA and nB phases if required can be found on J3 The image at Figure 2 3 shows typical si...

Страница 11: ......

Страница 12: ...please visit www deva co uk support downloads Or contact us at support deva co uk Deva Electronic Controls Limited 52 Woodside Business Park Birkenhead Wirral CH41 1EL Phone 44 0 151 647 3222 Fax 44 0 151 647 4511 Email sales deva co uk Website www deva co uk ...

Отзывы: