Page 1
Deva018 Single Axis Sine-Wave Interpolator
User’s Manual
Overview
«Hder_Sect_Title_1»
1
Overview
1.1
About this Manual
This manual covers the Deva018 Single Axis Sine Wave Interpolator and discusses features
and potential applications.
1.2
Deva018 Features
The Deva018 Single Axis Sine Wave Interpolator has been designed for use in motion and
control applications using a PC based system. It can be used for a wide range of
applications, such as manual Coordinate Measuring Machines (CMMs), automation and
process control, control system diagnostics, metrology and data acquisition.
This manual describes the installation/configuration of Deva018 and the facilities it offers.
For information regarding its use in conjunction with other Deva products, please refer to the
relevant User’s Manual/Programming Guide.
Note: Software support is an ongoing activity; if support for a particular application or
operating system is not detailed in our documentation as provided, please contact
to determine current, or future, availability.
1.2.1
Facilities
•
Accepts 1Vpp or 11µA signals
•
Input range 0.6Vpp - 1.2Vpp or 5µA - 16µA
•
Selectable interpolation factor: 10, 20, 50, 100
•
Handles marker/index channel
•
Maximum input frequency 125kHz
•
Maximum output frequency 5MHz
•
RS422 line driver output