65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 34 -
Graph History of Multipath
Button Assignment:
SB1
to
SB4
– lead to different screens of the menu
OK
– leads back to Main menu page.
Up/Down
– Change the currently displayed signal. The following signals can be selected:
• RF Level – from -10 to 110 in dBμV;
•
Multipath level from 0 to 50 in % (percent);
•
Total MPX deviation from 0 to 125 in kHz;
•
MPX power from -12 to 12 in dBr. Due to the 20 second integration of the MPX power
calculation the time span for MPX power graph is in minutes. Up to 48 minutes of MPX
power history is available;
•
Pilot level from 0 to 15 in kHz;
•
RDS level from 0 to 15 in kHz;
•
Left audio level from -60 to 10 in dB;
•
Right audio level from -60 to 10 in dB;
•
Frequency offset of the RF carrier from -50 to 50 in kHz;
•
Temperature in the device from -10 to 90°C.