- 91 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
Parameter Name
Type
Range
Default value [,Unit]
Description
For all Alarms
Trigger
TIMER
1 … 600, step 1
300, sec
Alarm active event delay
Release
TIMER
1 … 600, step 1
300, sec
Alarm idle event delay
SMS
ENUM
ON, OFF
OFF
SMS notification control
ENUM
ON, OFF
OFF
Email notification control
SMNP
ENUM
ON, OFF
OFF
SNMP notification control
GPO
ENUM
1, 2, 3, 4, 5, 6, 7, OFF
OFF
GPO pin assignment control
RF Alarm
Low threshold
INT
20 … (High threshold)
25, dBµV
Low alarm trigger level
High threshold
INT
(Low threshold) … 100
75, dBµV
High alarm trigger level
MPX Alarm
Low threshold
INT
0 … (High threshold)
30, kHz
Low alarm trigger level
High threshold
INT
(Low threshold) … 125
75, kHz
High alarm trigger level
MPXPWR Alarm
Low threshold
INT
-12 … (High threshold)
-8, dBr
Low alarm trigger level
High threshold
INT
(Low threshold) … 12
6, dBr
High alarm trigger level
Pilot Alarm
Low threshold
INT
0 … (High threshold)
4, kHz
Low alarm trigger level
High threshold
INT
(Low threshold) … 15
8, kHz
High alarm trigger level
RDS Alarm
Low threshold
INT
0 … (High threshold)
2.5, kHz
Low alarm trigger level
High threshold
INT
(Low threshold) … 15
6.5, kHz
High alarm trigger level
Left Alarm and Right Alarm
Low threshold
INT
-50 … (High threshold)
-40, dB
Low alarm trigger level
High threshold
INT
(Low threshold) … 5
0, dB
High alarm trigger level
Temperature Alarm
Low threshold
INT
0 … (High threshold)
20, °C
Low alarm trigger level
Содержание DB4005
Страница 5: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...