Enter the desired alarm recipients in e-mail 1 and/or e-mail 2 fields. Fill in your e-mail account
settings: Sender, Username and Password, Server, SNMP port and connection type. It is mandatory
the type of connection with the server to be specified from Connection - Regular, Encrypted. The
Server port will be changed accordingly. Please note that the most commonly used port will be
entered in the field. If the port that is to be used is different, change it manually to the correct value.
If you experience difficulties in the set-up, or would like to use DEVA account for sending
of alarm email notifications, press the [DEVA] button option, and complete the recipient emails
(E-mail 1 and E-mail 2) only. The other fields must be left blank, otherwise the email notification
option will not be working. Event though using the DEVA account eases the set-up process, we
recommend user account to be used for sending of email notifications, , and the DEVA account for
test purposes. When using DEVA account, please note that the stable 24/7 connection depends on
the mail service provider and cannot be guaranteed.
We recommend you to use the ‘Test’ button and generate a test e-mail, which upon success will
be delivered to the specified E-mail 1 and/or E-mail 2.
Example of Test E-mail Message:
DB4005 Test Message.
Please do not reply to this e-mail.
UECP Relay
The unit can relay the received RDS as a UECP stream. There are two possible options:
Option 1
– via UDP, where the device sends the received RDS as UECP encoded UDP packets
unconditionally to the specified IP Address and Port. The receiver could be an RDS/RBDS Encoder
SmartGen, other RDS Encoder, or Monitoring Software.
Option 2
– via TCP. The unit has built in server and a Monitoring Software to receive the UECP
encoded RDS data could be connected to the unit.
USB Port
Enable/Disable the USB port.
WARNING:
The applied changes will take effect upon pressing the “Save” button. All settings
marked with require Reboot, therefore the Save & Reboot button should be used.
NOTE:
The edited field will become red if the new value is invalid or out of range.