26.8.11
UNIGATE Fieldbus Gateway CANopen® - ProfibusDP V. 2.3
33
Deutschmann Automation GmbH & Co. KG
Technical data
The table below lists all tests, standards and regulations on the basis of which the module has
been tested.
No. Parameter
Data
Explanations
1
Vibration test
5 Hz
f
26 Hz, amplitude = 0.75 mm
26 Hz
f
500 Hz, acceleration = 20 m/s
2
Frequency sweep : 1 octave/min.
10 frequency sweeps each in x, y, z
(IEC 68-2-6Fc sinusoidal)
2
Shock test
Shock waveform = semi-sinusoidal
Acceleration = 15g (150 m/s
2
)
Shock duration = 11 ms
3 shocks in +/- direction in x, y, z
(IEC 68-2-27-Ea)
3
ESD
8 kV discharge in air
4 kV contact discharge
EN 50082-2
4
Electromagnetic fields 10 V/m
EN 50082-2
5
BURST
2 kV / 5 kHz supply voltage
1 kV / 5 kHz data lines
EN 50082-2
6
Emitted interference
Limit value class A
EN 55011
7
Approvals
CE mark
Profibus certification
Certificate of Conformity
PROFIBUS User Organisation