Deublin 1379 Series Скачать руководство пользователя страница 5

  
  

040-563

  

2018-10

Operating Manual

 Model/Series: 
 Number: 

       GB

 Version:

Rev. D 

Page 5 of 16 

©

DEUBLIN

for air and hydraulic

with elastomeric seals

 

Connection to a piping system with excessive pressure

  If excessive pressure is applied to the rotating unions, supply pipes can come off and cause 

personal injury or property damage.

 

Connection to fixed pipes

  If connection is via fixed pipes, the rotating unions may leak and the ball bearings may get 

damaged.

 

Conveying of media which are too hot

 

If the media exceed the maximum admissible temperature for the rotating union, the seals can 

be damaged which may result in leaky rotating unions and personal injury or property damage.

 

Application in ambient temperatures/with media temperatures below 3 °C 

  Rotating unions may be damaged if they are operated at temperatures (ambient or media) be-

low 3

 

°C. 

 

Operation without a medium (dry run)

  If the rotating unions are operated without a medium, the sealing surface of the rotating unions 

might fail prematurely.

 

Operation at maximum speed and with maximum pressure

  Speed and pressure must be adjusted to each another so that the rotating unions are not dam-

aged or fail prematurely (see model-specific installation drawing).

This list is not comprehensive and will be updated with results from product observation.

1.3 

Safety Instructions

This chapter provides information on the hazards when using rotating unions.

1.3.1  Hazards due to hot surfaces

Frictional heat and the temperature of the medium causes rotating unions to rise in temperature. Skin 

contact with heated rotating unions can cause injuries.

 

Use safety gloves and PPE (Personal Protective Equipment) protecting against heat when han-

dling the rotating union.

 

Attach a clearly visible danger sign visibly on/next to the rotating union in order to warn of 

danger.

1.3.2  Hazards due to incorrect hoses

For the connection of the rotating union to the machine, you have to choose appropriate hoses for the 

respective medium, which meet, the specifications for the application.

If you use incorrect hoses, they may become porous or burst. This can cause personal injury and/or 

property damage to components of the machine.

 

Use only hoses which are suitable for the media, the maximum system pressure and the maxi-

mum temperature for the machine.

1.3.3  Hazards due to the media

When working on the rotating union, injuries can be caused by skin or eye contact with the media.

 

Observe the safety instructions for the flow media. Observe the COSHH Safety Data Sheet for 

the flow media.

Содержание 1379 Series

Страница 1: ...l Series Number GB Version Rev D Page 1 of 16 DEUBLIN for air and hydraulic with elastomeric seals Rotating Unions Series 17 21 2117 1690 1790 1890 1379 1479 2300 D MPSS 000037 for air and hydraulic w...

Страница 2: ...4 Optional 1379 1479 use of support sleeves for vacuum applications__________________ 9 4 5 Connecting Options of the Rotating Union at the Machine Shaft_______________________ 9 4 6 Options of Hose...

Страница 3: ...nt Please follow the additional instruction Installation for a secure and correct installation of the rotating union The installation instruction is included with the delivered union 1 1 Intended Use...

Страница 4: ...ns ofthe17 21 2117 1690 1790 1890 1379 1479 2300 D and MPSS 000037 series The rotating unions are not suitable for the areas and applications described herein Use in such ar eas or for such applicatio...

Страница 5: ...maturely see model specific installation drawing This list is not comprehensive and will be updated with results from product observation 1 3 Safety Instructions This chapter provides information on t...

Страница 6: ...installation of the rotating union The installation instruction is included with the delivered union Install the hoses to the rotating union prior to mounting it at the machine shaft This does not app...

Страница 7: ...or surrounding objects can be dam aged Application notes and other useful information 2 Information as to this Manual The copyright as to this manual remains with DEUBLIN Subject to changes You can do...

Страница 8: ...0 m increased wear of the rotating union Please use the following classes of liquid media Class 5 in accordance with ISO 4406 2017 Code 17 15 12 or Class 6 in accordance with NAS 1638 Determine the re...

Страница 9: ...d together with the rotating unions of series 1379 and 1479 Component damage due to incorrect installation If the support sleeves are inserted into the channel with O ring already in position you risk...

Страница 10: ...forces to the rotat ing union The following figures show examples of installation Connect the rotating union with flexible hoses During operation flexible hoses prevent lateral loads on the bearings o...

Страница 11: ...side of the bracket and the hose connector Fig 7 Top view torque support 4 6 4 Optional Connection of a leakage line To prevent surrounding components from being damaged by escaping medium you can con...

Страница 12: ...edium the sealing surfaces of the rotating unions will be damaged Ensure that the rotating unions are operated with a medium Switch off the plant machine if the rotating unions are operated without me...

Страница 13: ...er leakage occurred at the rotating union see arrows If you detect leakage 1 Stop the machine 2 Replace worn out or leaking rotating unions with new ro tating unions 3 Replace defective hoses with new...

Страница 14: ...ns untrue or wobbles Thread and or concen tricity outside the admis sible tolerance 1 Stop the machine 2 Remove rotating union 3 Manufacture new thread or flange 4 Mount the rotating union according t...

Страница 15: ...andards regulations and directives In case of repair DEUBLIN disposes of all used parts 11 Spare Parts The rotating unions have a limited service life and include wearing parts All static and dynamic...

Страница 16: ...hone 34 93 221 1223 Fax 34 93 221 2093 e mail deublin deublin es DEUBLIN United Kingdom 6 Sopwith Park Royce Close West Portway Andover SP10 3TS UK Phone 44 1264 33 3355 Fax 44 1264 33 3304 e mail inf...