Table 3 : Technical specifications 

 

Power, total (Kw)

10

15

18

20

23

20

23

25

27

Power, first stage (Kw)

5

10

9

10

13

10

13

13

15

Net capacity (BTU/h)

34 120

51 180

61 420

68 240

78 480

68 240

78 480

78 480

92 130

Heating temperature rise range (F) 

1

40-50

45-60

50-75

55-75

60-80

55-75

60-80

60-80

60-80

Volts - Hertz - Phase
Electrical element #1 (Kw)

5

5

4

5

4

5

4

25

5

Electrical element #2 (Kw)

5

5

5

5

5

5

5

5

5

Electrical element #3 (Kw)

5

4

5

4

5

4

4

5

Electrical element #4 (Kw)

5

5

5

5

5

5

4

Electrical element #5 (Kw)

5

5

5

4

Electrical element #6 (Kw)

4

Blower motor Consumption (Amp. Max.)

6

6

6

6

6

13

13

13

13

Heating Elements Consumption (Amp)

41

61

74

82

94

82

94

104.2

111

Total Consumption (Amp) 

47

67

80

88

100

95

107

117.2

124

Blower speed at 0.50" W.C. static pressure

LOW MED-LOW MED-LOW MED-HIGH MED-HIGH MED-LOW MED-LOW MED-LOW MED-LOW

Blower speed at 0.20" W.C. static pressure

LOW MED-LOW MED-LOW MED-LOW MED-HIGH MED-LOW MED-LOW MED-LOW MED-LOW

Motor (HP) / number of speeds
Nominal blower size (diam. X width)

Overall dimensions (width x depth x height)
Supply
Return
Filter quantity and size
Shipping weight
Maximum cooling capacity

ELECTRICAL SYSTEM

GENERAL INFORMATION 

BLOWER DATA  (factory adjusted to a staic pressure of 0.5" W.C.)

(1) 20" x 20"

3 tons

SUPxx-M2401B

19" x 19"

12 x 10

2) Calculated on the basis of Norm C22.2 Nr. 236

1) Select a blower speed that will generate the specified temperature rise

20" x 20" x 36.5"

15" x 18"

RATINGS AND PERFORMANCE

5 tons

SUPxx-M2401A

1/3 HP  / 4 speeds

1 HP / 4 speeds

3 wires  120 / 240 - 60 - 1

10 x 8

48 Kg / 105 lbs

 
 

Table 4 : Airflow (CFM) - SUPREME with 1/3HP motor 

0,1

0,2

0,3

0,4

0,5

0,6

0,7

LOW

715

700

690

675

660

650

635

MED-LOW

935

900

870

835

800

770

735

MED-HIGH

1 090

1 050

1 010

970

930

890

850

HIGH

1 285

1 250

1 220

1 185

1 150

1 120

1 085

Airflow values in cubic feet per minute (CFM) rounded to nearest 5 CFM
Data taken with Air filter in place.

Blower 

speed

External static pressure (inche of W.C.)

 

 

 

Table 5 : Airlfow (CFM) - SUPREME with 1HP motor 

0,1

0,2

0,3

0,4

0,5

0,6

0,7

LOW

1 035

1 030

1 030

1 025

1 020

1 020

1 015

MED-LOW

1 315

1 300

1 285

1 270

1 255

1 240

1 225

MED-HIGH

1 715

1 650

1 590

1 525

1 460

1 400

1 335

HIGH

1 935

1 900

1 870

1 835

1 800

1 770

1 735

Airflow values in cubic feet per minute (CFM) rounded to nearest 5 CFM
Data taken with Air filter in place.

Blower 

speed

External static pressure (inche of W.C.)

 

Содержание SUPREME SUP10-M2401A

Страница 1: ...J1L 1V8 Caution Do not tamper with the unit or its controls Call a qualified service technician Printed in Canada Printed on 100 recycled paper MULTI POSITION INSTALLER SERVICE TECHNICIAN USE THE INF...

Страница 2: ...8 4 1 AIR FILTER 8 4 2 MOTOR LUBRICATION 8 5 0 FURNACE INFORMATION 9 TABLES Table 1 Supply air adjustment on heating mode 6 Table 2 Supply air adjustment on air cooling mode 6 Table 3 Technical speci...

Страница 3: ...tch or circuit breaker ii The air filter and how to change it check monthly and clean or replace if necessary f Before calling for service be sure to have the information of section 5 of your manual c...

Страница 4: ...o clearance to combustible material regardless of the heating capacity 2 2 2 Supply air ducts Ducts for furnaces with a heating capacity up to and including 20 k W can be installed with a zero clearan...

Страница 5: ...acement these must be copper wires only with same temperature rating as originals 2 5 INSTALLATION OF THE THERMOSTAT A thermostat must be installed to control the temperature of the area to be heated...

Страница 6: ...no way hinder access to the furnace panels 2 6 SUPPLY AIR ADJUSTMENTS On units equipped with 4 speed blower motors the supply air must be adjusted based on heating air conditioning output and the stat...

Страница 7: ...door is in place and the blower rail locking screws are well tightened 3 The blower speed adjustments for heating and air conditioning are appropriate and according to the specifications in this manu...

Страница 8: ...certain that the unit does not operate above the temperatures specified in the Technical Specifications Table 2 This is particularly important if a cooling coil or a heat pump has been installed in th...

Страница 9: ...ler name and address START UP RESULTS Voltage Total current consumed by the elements Supply air temperature Return air temperature Supply air duct static pressure Return air duct static pressure Total...

Страница 10: ...nd size Shipping weight Maximum cooling capacity ELECTRICAL SYSTEM GENERAL INFORMATION BLOWER DATA factory adjusted to a staic pressure of 0 5 W C 1 20 x 20 3 tons SUPxx M2401B 19 x 19 12 x 10 2 Calcu...

Страница 11: ...11 Figure 9 Furnace dimensions...

Страница 12: ...12 Figure 10 Wiring diagram 3 wires 10 kW...

Страница 13: ...13 Figure 11 Wiring diagram 3 wires 15 kW...

Страница 14: ...14 Figure 12 Wiring diagram 3 wires 18 20 kW...

Страница 15: ...15 Figure 13 Wiring diagram 3 wires 23 kW...

Страница 16: ...16 Figure 14 Wiring diagram 3 wires 27 kW...

Страница 17: ...17 Figure 15 PARTS LIST Supreme with 1 3 HP and 1 HP motor SUPxx M2401A or SUPxx M2401B B50130A dwg...

Страница 18: ...L 22A B04125 ELECTRICAL KIT 10kw 22B B04124 ELECTRICAL KIT 15kw 22C B04123 ELECTRICAL KIT 18 20kw 22D B04122 ELECTRICAL KIT 23 25kw 22E B04121 ELECTRICAL KIT 27kw 23 B04091 MOUNTING PLATE FOR ELECTRIC...

Отзывы: