Tableau 14: 2 week History Air Handler User Menu
2 week History (2 wK HIST)
Parameter
Indications
Comments
2wk AuxHT Hrs
XXX
2 Week Auxiliary Heat Hours of Operation
2wk AuxHT Cycls
XXXX
2 Week Auxiliary Heat Cycles
2wk G Hrs
XXX
2 Week Blower Hours of Operation
2wk G Cycles
XXXX
2 Week Blower Cycles
Tableau 15: Life History Air Handler User Menu
Life History (LIFE HIST)
Parameter
Indications
Comments
Total Days Pwrd
XXXX
Total number of days control has been powered
Aux HT Hrs
XXXXXX
Auxiliary Heat Hours of Operation
Aux HT Cycles
XXXXXX
Auxiliary Heat Cycles
G Hrs
XXXXXX
Continuous Fan Hours of Operation
G Cycles
XXXXXX
Continuous Fan Cycles
Tableau 16: Unit Info Air Handler User Menu
Unit Info
Parameter
Indications
Comments
Model Number
XXXX-XXXXXXXXXXXXXXXX
Unit Model Number
Serial Number
XXXXXXXXXXXXXXXXXXX
Unit Serial Number (not available if
control is replaced)
Software Vers
XXXXXX
Control Software Version
Tableau 17: Setup Air Handler User Menu
Setup
Parameter
Options
Comments
Return Air Sense
Off, On
If Return Air Sensor is field installed, turn On.
Factory Default is Off
Supply Air Sense
Off, On
If Supply Air Sensor is field installed, turn On.
Factory Default is Off
Stage Aux Heat
Off, On
If W1 and W2 staging is desired, W1/W2 jumper
must be removed from heater kit; then turn On. Factory
Default is Off
Aux Airflow Sel
Off, On
If reduced Electric Heat Airflow is needed for 15 KW
and below, turn On. Factory default is Off
Reset All Dflts
No, Yes
Resets the Air Handler to the Factory Default
Configuration by selecting Yes
Tableau 18: Dipswitch Air Handler User Menu
Dipswitch*
Dip Switch
Indications
Comments
Cool Airflow
XXXXCFM
View Airflow Dipswtiches
HT Pump Airflow
XXXXCFM
View Heat Pump Airflow Dipswitch Settings
Cool Air Adj
-10%, 0%, 10%
View Airflow Trim Settings
On-Demand Dehum
On, Off
Activate Dehumidification Feature
* Dipswitch status is not required when the system is set up for 4-wire communications. It is only displayed
when a conventional 24V thermostat input is active.